DVH-335UB/XNRC
60
1
2
3
4
1
2
3
4
C
D
F
A
B
E
EDC. Image of the test mode
[Note] Image is the same for both EDC1 and EDC2.
(1)
(2)
EDC1/2 test mode
0000 0000
Layer 0 selection
Layer 1 selection
0000 0000
0100 0000
1003 0000
1103 0000
(5)
[Note] The display is updated at 0.5 seconds interval until 0/1 layer is selected or Eject is effected.
(1)-(4)
ID designation
EDC1/2 start
Layer 0: 10** ****
Layer 1: 11** ****
[Note] ** **** is the ID designation value
Layer 0: 20** ****
Layer 1: 21** ****
[Note] ** **** is the present ID designation value
**** ****
[Note] **** **** is the present ID designation value
Legend:
… Key operation
… Operational state
… The content displayed on the DVD mechanism (video only)
8 characters data is sent to the product side (HOST) by UART communication.
[Note] Eject can be effected any time during the EDC test mode.
Eject
After completion of EJECT operation
EJECT operation
Test mode Eject
Image of the LD power on time mode.
LD power on time mode
0000 0000
CD LD power on
time indication
DVD LD power on
time indication
10** ****
[Note] ** **** is the CD LD
power on time.
20** ****
[Note] ** **** is the DVD LD
power on time.
(1)
(2)
CD LD power on
time setting
Setting time
designation
30** ****
[Note] ** **** is the setting time.
Setting time
registration
DVD LD power on
time setting
Setting time
designation
40** ****
[Note] ** **** is the setting time.
(5)
(6)
(1)-(4)
(1)-(4)
(5)
(5)
(8)
10** ****
[Note] ** **** is the CD LD
power on time.
Setting time
registration
(8)
20** ****
[Note] ** **** is the DVD LD
power on time.
[Note] If the power on time is 999999 hours or more, it is always reported as 999999 hours.
[Note] If the power on time is “*E** ****”, the value may not be correct due to the life of the flash memory.
[Method of setting time designation]
Designate the digit by command (1) and (2). UP/DOWN of numbers by command (3) and (4).
Fix by command (5). Cancel by command (8).
Legend:
… Key operation
… Operational state
… The content displayed on the DVD mechanism (video only)
8 characters data is sent to the product side (HOST) by UART communication.
Not for service use
Содержание DVH-335UB/XNRC
Страница 17: ...DVH 335UB XNRC 17 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 45: ...DVH 335UB XNRC 45 5 6 7 8 5 6 7 8 C D F A B E Side A COMPOSITE GNDV Fig 11 3 VIDEO signal check point ...
Страница 48: ...DVH 335UB XNRC 48 1 2 3 4 1 2 3 4 C D F A B E Side A DGND1 IC1501 50pin Fig 13 3 48 MHz check point ...
Страница 50: ...DVH 335UB XNRC 50 1 2 3 4 1 2 3 4 C D F A B E Side A SCLOCK SDATA D CP_ RESET D DGND2 ...
Страница 56: ...DVH 335UB XNRC 56 1 2 3 4 1 2 3 4 C D F A B E 5 5 CONNECTOR FUNCTION DESCRIPTION ...
Страница 66: ...DVH 335UB XNRC 66 1 2 3 4 1 2 3 4 C D F A B E 1 Have a specified part Handling OK Handling NG How to have it ...
Страница 82: ...DVH 335UB XNRC 82 1 2 3 4 1 2 3 4 C D F A B E 9 2 EXTERIOR 1 B ...
Страница 84: ...DVH 335UB XNRC 84 1 2 3 4 1 2 3 4 C D F A B E 9 3 EXTERIOR 2 A 601 A B B A ID ...
Страница 88: ...DVH 335UB XNRC 88 1 2 3 4 1 2 3 4 C D F A B E A GEM1045 B GEM1038 C GEM1024 A C C A A C C C C C A A ...
Страница 89: ...DVH 335UB XNRC 89 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 107: ...DVH 335UB XNRC 107 5 6 7 8 5 6 7 8 C D F A B E ...