PIONEER DVD-V7200 Industrial DVD Player RS-232 Command Protocol Manual
- 60 -
7 Bytes integer <CR> (=YYMMDDWWHHMMSS<CR>)
Explanation
:
The real time clock may be set using the following format:
YY
the last two digits of year
MM
month
DD
date
WW
day, 00 means Monday, 06 means Sunday
HH
hour 24-hour format
MM
minute
SS
second
NOTE: Input the 7-Bytes integer as a single entry. If an integer is less than 7-Bytes
in length, the player returns an error message.
Execution :
Command String
Status Return
DVD-V7200
WW<CR>
R<CR>
Set Real Time Clock setting mode
98040102083025<CR>
R<CR>
Sets Wednesday, April First,
8:30:25 AM , 1998
6.20
Advanced Feature Menu Set
Function :
The current setting of Industrial Player Menu is rewritten
Format
:
Integer MS
Explanation
:
The command rewrites the setting of Industrial Player Menu as like
follows. Basically, the setting is expressed with some integer value. The value is
made up with the sum of each argument you want. The default is 0 when the player
was shipped. The player returns an error code if the command is issued when the
player is showing Industrial Player Menu on the screen.
The current setting is gotten with the Advanced Feature Menu Request command
(?S).
Description
Argument
Function
0
1
1
WEEKLY TIMER
OFF
ON
2
POWER ON START
OFF
ON
4
TITLE PLAY MODE
SINGLE
ALL
8
16
REPEAT MODE
(0) OFF, (8) CHAPTER
(16) TITLE, (24) DISC *1)
32
BAUD RATE
4800bps
9600bps
64
TRAY LOCK
OFF
ON
128
BLACKBOARD LOCK
OFF
ON
Содержание DVD-V7200
Страница 4: ......
Страница 16: ......
Страница 20: ...PIONEER DVD V7200 Industrial DVD Player RS 232 Command Protocol Manual 12 ...
Страница 56: ...PIONEER DVD V7200 Industrial DVD Player RS 232 Command Protocol Manual 48 ...
Страница 87: ...DVD V7200 Internal Registers 79 ...
Страница 91: ...DVD V7200 Internal Registers 83 9 2 2 Diode Matrix Circuit ...
Страница 106: ......