OB-U0192
5
Name of Parts/Function/Setting
3 . Device Configuration Jumper
Switch turns on by inserting short socket.
Make sure that drive power is turned off before jumper setting is changed.
Only MA is
“
on
”
at the time of shipping from the plant.
Pin
Name
Function
1
MA
on The drive is used in
Master Mode
.
2
SL
on The drive is used in
Slave Mode
.
3
CS
on Using
“
Cable Select
”
function.
4
Reserved
5
Reserved
4 . Audio Output
A connector for output of analog audio.
This connector is compatible with
“
Molex 70553
”
, choose a connection cable which matches with the
connector.
Pin
Name
Function
1
L
Left channel audio output
2
G
Ground
3
G
Ground
4
R
Right channel audio output