DEH-MG2047ZF/XU/UC
59
5
6
7
8
5
6
7
8
C
D
F
A
B
E
6.3 TEST MODE(CD)
72
01
* *
3) To select the LOAD motor, press the "3" key.
[Key operations]
Select the motor to be operated by using one of the following three keys: 1, 2,3, and 6.
To move the selected motor, use the "SEEK UP / SEEK DOWN" key.
While the key is being pressed, the motor will continue to move.
Track
Min
Sec
CAM motor selected
Mech. test mode
Display
1) To select the CAM motor, press the "1" key.
2) To select the ELV motor, press the "2" key.
72
02
Track
Min
Sec
ELV motor selected
Mech. test mode
Display
72
00
Track
Min
Sec
LOAD motor selected
Mech. test mode
Display
"SEEK UP" key: to load a disc.
"SEEK DOWN" key: to eject the loaded disc.
"SEEK UP" key: to move in the
ELV UP direction
"SEEK DOWN" key: to move in the
ELV DOWN direction
"SEEK UP" key: to move in the
CAM PLAY direction
"SEEK DOWN" key: to move in the
CAM ELV direction
LOADSW2
The status of loading switches
LOADPHT
LOADSW1
Half
emp
fill
OFF
ON
OFF
ON
ON
OFF
CAMOK
The status of CAM switches
CAMLOAD
CAMCLMP
E
L
V
L
I
F
T
C
L
M
P
P
L
A
Y
04
06
07
05
01
OFF
ON
OFF
ON
OFF
ON
CD Mech. Test Mode
Display
Display
03
07
05
02
05 07
01
03
Display
12
04
00
02
01
03
01
13
Disc 6
Disc 2
Disc 1
Door closes.
Door opens incompletely.
Door opens.
Notes:
To protect the mechanism from unexpected damages, keep the following points in mind:
1. Before moving the CAM motor from the ELV position to the LIFT position,
be sure to move the ELV motor to select the disc 1 to 6.
2. Before moving the CAM motor from the CLMP position to the LIFT position,
be sure to select the SPDL claws to release the disc clamp.
Note:
The mechanical operations such as loading, ejection and disc change are controlled by the highly sophisticated method.
Before entering this test mode, fully grasp how the mechanism is controlled, by referring to the mechanism operation flowchart.
Note:
Before moving the ELV motor, be sure to move the CAM motor to the ELV position or LIFT
position first. If not, the mechanism may be damaged.
When the CAM motor is set to the ELV position, do not move the ELV motor from the
door open position to the door closed position.
* *
* *
[4] + [6]
Test Mode In
[Key]
Operation
Display
[CD]
Source CD
[1]
Mech Test In
[1]
CAM MOTOR
Selection
MIN
SEC
TRK
01
**
72
[2]
ELV MOTOR
Selection
MIN
SEC
TRK
02
**
**
72
[6]
DISC CLAMP
SELECTION
MIN
SEC
TRK
03
**
72
[5]
SELECTION
RESET
MIN
SEC
TRK
**
**
72
[SCAN]
Mech Test In
MIN
SEC
TRK
**
**
**
[3]
LOAD MOTOR
Selection
MIN
SEC
TRK
02
72
MIN
SEC
TRK
**
**
**
MIN
SEC
TRK
**
**
72
Содержание DEH-MG2047
Страница 23: ...DEH MG2047ZF XU UC 23 5 6 7 8 5 6 7 8 C D F A B E B KEYBOARD UNIT B POWER VOLUME ...
Страница 33: ...DEH MG2047ZF XU UC 33 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 36: ...DEH MG2047ZF XU UC 36 1 2 3 4 1 2 3 4 C D F A B E A A TUNER AMP UNIT IC Q 1 ...
Страница 37: ...DEH MG2047ZF XU UC 37 5 6 7 8 5 6 7 8 C D F A B E A SIDE B ...
Страница 39: ...DEH MG2047ZF XU UC 39 5 6 7 8 5 6 7 8 C D F A B E B B KEYBOARD UNIT SIDE B IC Q A CN724 ...
Страница 41: ...DEH MG2047ZF XU UC 41 5 6 7 8 5 6 7 8 C D F A B E C C CONTROL UNIT G2F SIDE B IC Q ...
Страница 76: ...DEH MG2047ZF XU UC 76 1 2 3 4 1 2 3 4 C D F A B E 7 2 2 DISPLAY VF CAW1806 ...