37
DEH-M7317ZH
•
Note :
The grating angle of the PU unit cannot be adjusted after the PU unit is changed. The PU unit in the CD mecha-
nism module is adjusted on the production line to match the CD mechanism module and is thus the best adjusted
PU unit for the CD mechanism module. Changing the PU unit is thus best considered as a last resort. However, if
the PU unit must be changed, the grating should be checked using the procedure below.
•
Purpose :
To check that the grating is within an acceptable range when the PU unit is changed.
•
Symptoms of Mal-adjustment :
If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to perform
track search operations, or taking a long time for track searching.
•
Method :
• Measuring Equipment
• Oscilloscope, Two L.P.F.
• Measuring Points
• E, F, REFOUT
• Disc
• ABEX TCD-784
• Mode
• TEST MODE
•
Checking Procedure
1. In test mode, load the disc and switch the 5V regulator on.
2. Using the
SEEK/SKIP+
and
SEEK/SKIP-
buttons, move the PU unit to the innermost track.
3. Press key
SCAN/RPT
to close focus, the display should read "91". Press key
2
to implement the tracking balance
adjustment the display should now read "81". Press key
SCAN/RPT
2 times. The display will change, returning to
"81" on the fourth press.
4. As shown in the diagram above, monitor the LPF outputs using the oscilloscope and check that the phase differ-
ence is within 75° . Refer to the photographs supplied to determine the phase angle.
5. If the phase difference is determined to be greater than 75° try changing the PU unit to see if there is any
improvement. If, after trying this a number of times, the grating angle does not become less than 75° then the
mechanism should be judged to be at fault.
•
Note
Because of eccentricity in the disc and a slight misalignment of the clamping center the grating waveform may be
seen to "wobble" ( the phase difference changes as the disc rotates). The angle specified above indicates the aver-
age angle.
•
Hint
Reloading the disc changes the clamp position and may decrease the "wobble".
F
REFO
E
100k
Ω
390pF
100k
Ω
390pF
E
REFO
F
REFO
L.P.F.
L.P.F.
CONTROL UNIT
Xch
Ych
Oscilloscope
6.2 CHECKING THE GRATING AFTER CHANGING THE PICKUP UNIT
Содержание DEH-M7317ZH
Страница 3: ...3 DEH M7317ZH ...
Страница 4: ...4 DEH M7317ZH 2 1 EXTERIOR 2 EXPLODED VIEWS AND PARTS LIST ...
Страница 6: ...6 DEH M7317ZH 2 2 CD MECHANISM MODULE ...
Страница 21: ...21 DEH M7317ZH ...
Страница 23: ...23 DEH M7317ZH 5 6 7 8 5 6 7 8 D C B A TESTA PCLA ANTENNA FM AM TUNER UNIT FRONT A SIDE A ...
Страница 24: ...24 DEH M7317ZH 1 2 3 4 1 2 3 4 D C B A A A TUNER AMP UNIT ...
Страница 25: ...25 DEH M7317ZH 5 6 7 8 5 6 7 8 D C B A A SIDE B ...
Страница 27: ...27 DEH M7317ZH 1 2 3 4 1 2 3 4 D C B A A CN602 B KEYBOARD UNIT B SIDE B ...
Страница 29: ...29 DEH M7317ZH 1 2 3 4 D C B A 1 2 3 4 CLAMP C SIDE B C CONTROL UNIT ...
Страница 38: ...38 DEH M7317ZH Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...
Страница 46: ...46 DEH M7317ZH 7 1 2 CONNECTOR FUNCTION DESCRIPTION ANTENNA JACK ...