8. EACH SETTING AND ADJUSTMENT
8.1 PCL OUTPUT CONFIRMATION
9. EXPLODED VIEWS AND PARTS LIST
9.1 PACKING
-
PCL Output
In the normal operation mode (with the detachable panel installed, the ACC switched ON, the standby mode cancelled),
shift the TESTIN IC601(Pin 112) terminal to H. The clock signal is output from the SCET IC601(Pin 43) terminal.
The frequency of the clock signal is 1 Hz. The clock signal should be 1 Hz ± 0.000 04 Hz.
If the clock signal is out of the range, the X'tal (X601) should be replaced with new one.
N
OTES : Parts marked by "
*
" are generally unavailable because they are not in our Master Spare Parts List.
The
>
mark found on some component parts indicates the importance of the safety factor of the part.
Therefore, when replacing, be sure to use parts of identical designation.
Screw adjacent to mark on the product are used for disassembly.
For the applying amount of lubricants or glue, follow the instructions in this manual.
(In the case of no amount instructions,apply as you think it appropriate.)
" "