46
CDX-P650
Key
Mechanism Test Mode
(Example)
BAND
Back to the test mode
UP
Playing the mechanism
DOWN
Playing the mechanism
7
Mechanism test mode in
8
–
9
TRAY/ELV select
10
–
11
–
12
Operation step select
Note: Eject and CD on/off is performed in the same procedure as that for the normal mode.
(3) Cause of Error and Error Code
Code
Class
Contents
Description and cause
40
Electricity
Off focus detected.
FOK goes low.
→
Damages/stains on disc, vibrations or failure on servo.
41
Electricity
Spindle unlocked.
FOK = Low continued for 50 msec.
→
Damages/stains on disc, vibrations or failure on servo.
42
Electricity
Sub-code unreadable.
Sub-code was unreadable for 50 msec.
→
Damages/stains on disc, vibrations or failure on servo.
43
Electricity
Sound skipping detected.
Last address memory function was activated.
→
Damages/stains on disc, vibrations or failure on servo.
Note: Mechanical errors during aging are not displayed.
The error codes should be indicated in the same way as in the normal mode.
(4) Display of Operational Status (CPOINT) during Setup
Status No. Contents
Protective action
00
CD
+
5V ON process in progress.
None
01
Servo LSI initialization (1/3) in progress.
None
02
Servo LSI CRAM initialization in progress.
None
03
Servo LSI initialization (2/3) in progress.
None
04
Offset adjustment (1/3) in progress.
None
05
Offset adjustment (2/3) in progress.
None
06
Offset adjustment (3/3) in progress.
None
07
FZD adjustment in progress.
None
08
Servo LSI initialization (3/3) in progress.
None
10
Carriage move to home position started.
None
11
Carriage move to home position started.
None
12
Carriage is moving toward inner diameter.
Specified 10 seconds has been passed or failure
on home switch.
13
Carriage is moving toward outer diameter.
Specified 10 seconds has been passed or failure
on home switch.
14
Carriage outer kick in progress.
None
15
Carriage outer diameter feed (1 second) in progress.
None
20
Servo close started.
None
21
Pre-processing for focus search started.
None
22
Spindle rotation and focus search started.
None
23
Waiting for focus close (XSI
=
Low).
Specified focus search time has been passed.
24
Standing by after focus close is over.
Specified focus search time has been passed.
25
Focus search preprocessing is in
None
progress while setup protection is turned on.
Содержание CDX-P650
Страница 6: ...6 CDX P650 2 2 EXTERIOR ...
Страница 8: ...8 CDX P650 2 3 CD MECHANISM MODULE ...
Страница 14: ...14 CDX P650 1 2 3 4 1 2 3 4 D C B A A2 2 A 1 2 SYSTEM CONTROLLER EWmodel UC ESmodel ...
Страница 22: ...22 CDX P650 1 2 3 4 1 2 3 4 D C B A SIDE A B POWER UNIT B CN701 A CORD 4 2 POWER UNIT IP BUS ...
Страница 23: ...23 CDX P650 D C B A 1 2 3 4 1 2 3 4 B POWER UNIT B SIDE B ...
Страница 25: ...25 CDX P650 D C B A 1 2 3 4 1 2 3 4 E 4 5 MOTOR PCB MOTOR PCB E C ...
Страница 30: ...30 CDX P650 Grating waveform 45 0 75 60 30 90 Echt Xch 20mV div AC Fcht Ych 20mV div AC ...
Страница 48: ...48 CDX P650 7 3 BLOCK DIAGRAM A C D E ...
Страница 49: ...49 CDX P650 B ...