39
CDX-P2050VC,P2050VN,P2050VS
• Note :
CD mechanism modules the grating angle of the pickup unit cannot be adjusted after the pickup unit is changed.
The pickup unit in the CD mechanism module is adjusted on the production line to match the CD mechanism
module and is thus the best adjusted pickup unit for the CD mechanism module. Changing the pickup unit is thus
best considered as a last resort. However, if the pickup unit must be changed, the grating should be checked
using the procedure below.
• Purpose :
To check that the grating is within an acceptable range.
• Symptoms of Mal-adjustment :
If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to perform
track search operations, or track searching taking a long time, may appear.
• Method :
• Measuring Equipment
• Oscilloscope, Two L.P.F.
• Measuring Points
• E, F, REFO
• Disc
• ABEX TCD-784
• Mode
• TEST MODE
• Checking Procedure
1. Enter Test mode, then select Multi-CD player and switch the 5V regulator on.
2. Using the TRK+ and TRK- buttons, move the pickup unit to the innermost track.
3. Press key 9 to close focus, the display should read "91". Press key 9 2 times. Enter Rough Servo mode. Press key
8 to implement the tracking balance adjustment the display should now read "81".
4. As shown in the diagram above, monitor the LPF outputs using the oscilloscope and check that the phase differ-
ence is within 75° . Refer to the photographs supplied to determine the phase angle.
5. If the phase difference is determined to be greater than 75° try changing the pickup unit to see if there is any
improvement. If, after trying this a number of times, the grating angle does not become less than 75° then the
mechanism should be judged to be at fault.
• Note
Because of eccentricity in the disc and a slight misalignment of the clamping center the grating waveform may be
seen to "wobble" ( the phase difference changes as the disc rotates). The angle specified above indicates the aver-
age angle.
• Hint
Change the disc changes the clamp position and may decrease the "wobble".
REFO
E
F
E
F
L.P.F.
L.P.F.
CD CORE UNIT
Xch
Ych
Oscilloscope
100k
Ω
100k
Ω
390pF
390pF
6.1 CHECKING THE GRATING
-
Checking the Grating After Changing the Pickup Unit
6. ADJUSTMENT
Содержание CDX-P2050VC/X1N/UC
Страница 6: ...6 CDX P2050VC P2050VN P2050VS 2 2 EXTERIOR ...
Страница 8: ...8 CDX P2050VC P2050VN P2050VS 2 3 CD MECHANISM MODULE ...
Страница 13: ...13 CDX P2050VC P2050VN P2050VS 5 6 7 8 5 6 7 8 D C B A B POWER UNIT F CN303 ...
Страница 14: ...14 CDX P2050VC P2050VN P2050VS 1 2 3 4 1 2 3 4 D C B A F VOICE UNIT G PCB ASSY ...
Страница 15: ...15 CDX P2050VC P2050VN P2050VS 5 6 7 8 5 6 7 8 D C B A B CN922 ...
Страница 18: ...18 CDX P2050VC P2050VN P2050VS 1 2 3 4 1 2 3 4 D C B A A2 2 A 1 2 SYSTEM CONTROLLER PD5512B ...
Страница 27: ...EJECT RESET MAG IC Q 27 CDX P2050VC P2050VN P2050VS D C B A 1 2 3 4 1 2 3 4 A SIDE B CD CORE UNIT A ...
Страница 29: ...29 CDX P2050VC P2050VN P2050VS D C B A 1 2 3 4 1 2 3 4 B POWER UNIT B SIDE B ...
Страница 33: ...33 CDX P2050VC P2050VN P2050VS D C B A 1 2 3 4 1 2 3 4 F VOICE UNIT F SIDE B ...
Страница 40: ...40 CDX P2050VC P2050VN P2050VS Grating waveform 45 0 75 60 30 90 Echt Xch 20mV div AC Fcht Ych 20mV div AC ...