44
CDX-P1250
-
Error Messages
If a CD is not operative or stopped during operation due to an error, the error mode is turned on and cause(s) of the
error is indicated with a corresponding number. This arrangement is intended at reducing nonsense calls from the
users and also for facilitating trouble analysis and repair work in servicing.
(1) Basic Indication Method
1) When SERRORM is selected for the CSMOD (CD mode area for the system), error codes are written to DMIN (min-
utes display area) and DSEC (seconds display area). The same data is written to DMIN and DSEC. DTNO remains
in blank as before.
2) Head unit display examples
Depending on display capability of LCD used, display will vary as shown below. xx contains the error number.
8-digit display
6-digit display
4-digit display
ERROR–xx
ERR–xx
E–xx
OR
Err–xx
* When the system is manufactured for an OEM basis, the error display will be configured according to the customer
specification.
(2) Error Code List
Code
Class
Displayed error code Description of the code and potential cause(s)
10
Electricity
Carriage Home NG
CRG can't be moved to inner diameter.
CRG can't be moved from inner diameter.
→
Failure on home switch or CRG move mechanism.
11
Electricity
Focus Servo NG
Focusing not available.
→
Stains on rear side of disc or excessive vibrations on REWRITABLE.
12
Electricity
Spindle Lock NG
Spindle not locked. Sub-code is strange (not readable).
→
Failure on spindle, stains or damages on disc, or excessive vibrations.
Subcode NG
A disc not containing CD-R data is found. Turned over disc are found,
though rarely.
→
Failure on home switch or CRG move mechanism.
RF AMP NG
An appropriate RF AMP gain can't be determined.
→
CD signal error.
17
Electricity
Setup NG
APC protection doesn't work. Focus can be easily lost.
→
Damages or stains on disc, or excessive vibrations.
30
Electricity
Search Time Out
Failed to reach target address.
→
CRG tracking error or damages on disc.
A0
System
Power Supply NG
Power (VD) is ground faulted.
→
Failure on SW transistor or power supply (failure on connector).
A1
System
Mechanism power
Mechanism elevation reference voltage is out of
failure
prescription.
→
EREF adjustment VR and/or power abnormal.
50
Mecha-
An error upon
MAG switch release time has time out.
nism
ejection
Elevation time out when eject.
60
Mecha-
An error while putti-
Tray in / out time has time out.
nism
ng in and out the tray Tray is caught when put in.
Содержание CDX-P1250
Страница 6: ...6 CDX P1250 2 2 EXTERIOR ...
Страница 8: ...8 CDX P1250 2 3 CD MECHANISM MODULE ...
Страница 14: ...14 CDX P1250 1 2 3 4 1 2 3 4 D C B A A2 2 A 1 2 SYSTEM CONTROLLER EWmodel UC ESmodel ...
Страница 22: ...22 CDX P1250 1 2 3 4 1 2 3 4 D C B A SIDE A B POWER UNIT B CN701 A CORD 4 2 POWER UNIT IP BUS ...
Страница 23: ...23 CDX P1250 D C B A 1 2 3 4 1 2 3 4 B POWER UNIT B SIDE B ...
Страница 25: ...25 CDX P1250 D C B A 1 2 3 4 1 2 3 4 E 4 5 MOTOR PCB MOTOR PCB E C ...
Страница 30: ...30 CDX P1250 Grating waveform 45 0 75 60 30 90 Echt Xch 20mV div AC Fcht Ych 20mV div AC ...
Страница 48: ...48 CDX P1250 7 3 BLOCK DIAGRAM A C D E ...
Страница 49: ...49 CDX P1250 B ...