58
CDJ-1000
Player
1
VCO Free-running Adjustment
•
Power ON
•
None disc
•
The position of TEMPO
slider is set to 0
•
DOUT OFF
Oscilloscope
V: 50mV/div.
H: 10msec/div.
DC mode
Probe (10:1)
CH1
CH2
(X)
(Y)
VR601
MAIN ASSY
6.4 ELECTRICAL ADJUSTMENT
MAIN ASSY
GND
START
DC voltage
2.5
±
0.2V
Objective : To optimize the VCO free-running frequency
When not properly adjusted :
• Master Tempo does not function normally.
• TEMPO display does not become the same as that
of actual voice tempo.
VCO IN