CD-BTB100/XN/EW5
7
5
6
7
8
5
6
7
8
C
D
F
A
B
E
-
Test mode (using spectrum analyzer)
1. Cautions
If there is a spectrum analyzer supporting 2.4 GHz at the service site, confirmation of
transmission carrier becomes possible.
Since CD-BTB100 cannot operate singly, the main set with IP-BUS control is required.
Carrier existence is checked by removing the product case and applying the probe onto
the "ANT" land of the base unit.
Since it is done by probe connection, the level cannot be confirmed accurately.
2. Function outline
Simple operation check on Bluetooth is executed in test mode using a spectrum analyzer
supporting 2.4 GHz.
Output check on Bluetooth unit
3. Configuration diagram
Spectrum analyzer supporting 2.4 GHz
4. Procedure for test mode startup
1. Test mode startup
Start up the power supply by
simultaneously pressing 4+6 keys and
set the Head Unit mode to test mode.
2. Mode switching
Use the BAND/ key to switch from
production engineering test mode
to authentication/design test mode.
3. Display switches as
shown on the left figure
Switch display using the right key
and set the 5 Local TX no modula-
tion test mode.
Use key 1 to set the Local TX no
modulation detail setup mode.
4. To Local TX no modulation
detail
mode
Use key 3 to switch the frequency.
"Transition of display"
"Transition of display"
"Operation"
"Operation"
C N : W A I T
Initial screen for production engineering test mode
BAND key
L O O P . B _ S
Initial screen for authentication/design test mode
Local TX no modulation detail setting
TX Frequency
T _ 2 4 0 2
Key 3
Key 4
T _ 2
T _ 2
T _ 2
4
4
4
4
8
9
1
0
5
1 Loop Back test:
L O O P . B _ S
Right key
Left key
2 Page Scan test:
P . S C A N _ S
3 Inquiry Scan test:
I
. S C A N _ S
4 Local TX test:
L . T X
_ S
5
Local TX no modulation test:
Selecting
Local TX no modulation test:
Executing
L . T X N M _ S
L . T X N M _ E
Key 1
Key 2
To Loop Back test