CONTENTS
Page
PRECAUTIONS ................................................................................... 1
INSTALLATION INFORMATION .......................................................... 2
ACCESSORIES ................................................................................... 3
INDOOR UNIT INSTALLATION .......................................................... .4
OUTDOOR UNIT INSTALLATION ..
…
…
…
..
..
..
.
…
…
…
…
…
..
..
..
..
..
…
…
…
…
7
INSTALLING
THE
REFRIGERANT
PIPE
…
…
..
..
..
..
..
.
…
…
…
…
…
..
..
…
..
…
.9
CONNECTING
THE
DRAIN
PIPE..............….....................................12
ELECTRICAL
WIRING
WORK...........................................................13
INSTALLATION OF THE DECORATION PANEL
…
…
…
…
…
…
…
…
…
…
.15
TEST OPERATION ............................................................................ 16
PRECAUTIONS
.
Keep
this
manual in an easily accessible location.
. .
Read
this
manual
extensively
before starting
up
the
units.
.
For safety purposes, any unit operators must read the
following cautions carefully.
Installation
must
be
performed
in
accordance
with
the
requirement
of
NEC
and
CEC,
by
authorized
personnel
only.
The
saf
e
ty
precautions
listed
here
are
divided
into
two
categories.
A
WARNING
If these warnings are not adhered to,
the
unit
may cause
severe property
damage,
personal
injury,
or
loss
of
life.
A
CAUTION
If these cautions are not adhered to,
the
unit
may cause
minor
to
moderate
property
damage or
personal
injury.
Aft
e
r
completing
the
installation,
make
sure
that
the
unit
ope
「
ates
properly
during
the
start-up
operation.
Please
instruct
the
customer
on
how
to
operate
the
unit
and on
keepin
g
it
maintained. Also,
inform
customers that
they
should
store
this
installation
manual,
along
with
the
owner's manual,
for
future
reference.
A
WARNING
Be
sure to only hir
e
trained
and
qualified
service
personnel
to
install, repair,
or
service
the
equipment.
Improper
installation,
repair,
and
maintenance
may
result
in
electric
shocks,
short-circuits,
leaks,
fire,
or
other
damage
to
the equipment.
Install strictly
according
to
these
installation
instructions. If
installation
is
done improperly,
it
can lead to
water
leakage,
electrical shock,
and
fire.
When
installing
the
unit
inside
a
small
room,
take
measures
to
keep the
refrigerant
concentration
from
exceeding allowable
safety
limits,
in
the
event
of
ref
「
igerant
leakage. Contact
the
place
of
purchase
for
mo
「
e
information.
Excessive refrigerant
in
a
closed
ambient environment
can
lead
to
oxygen
deficiency.
Use
the
attached
accessories
and
specified
parts lists
for
installation. Be sure this list is closely adhered to, otherwise, it
can
cause
the
set
to
fall,
or result in water leakage,
electrical
shock,
or
fire.
Install
in
a
strong,
firm
location
that
can
withstand the
entirety of
the set's
weight.
If
the structural
integrity
is insufficient,
or
installation
is
improperly
done, the
set
can possibly
drop
to
cause
injury.
The
appliance
must
be
installed >2.5m/8.2 ft
above the
floor.
The
appliance
must
not
be
installed
in
the
laundry area.
Before
obtaining
access
to
terminals,
all
supply
circuits
must
be
disconnected.
The
appliance
must
be
positioned
so
that
the
plug
is
accessible
.
The
enclosure
of
the
appliance
should
be
marked
by
word,
or
by symbols,
with
the
direction
of
the
fluid
flow.
For
electrical
work,
follow
all
local and
national
wiring
standards
and regulations, as well as these
installation
instructions.
An
independent circuit
and
single
outlet
must
be
used. If the
electrical
circuit
capacity
is
not
enough,
o
「
there is a defect
in
the electrical work,
it
can lead to
electrical
shock
or
fire.
Use
the
specified
cable,
and
tightly connect
and
clamp
the
cable so
that
no
external
force
will
be
acted
upon
the
terminal. If
the connections
or
fixtures
are
not
perfect,
it
can
cause
heat-up
and
eventual fire at
the
connection site.
Wiring
routing
must
be
properly
arranged
so
that the
control
board cover
is
fixed
properly.
If the
control
board
cover
is
not
fixed
perfectly,
it
might
cause
heat-up at
connection
point
of
terminal,
fire,
or
electrical
shock.
If the
supply
cord
is
damaged,
it
must
be
replaced
by
the
manufacturer, service
agent,
or
a
similarly
qualified
person, in
order
to
avoid
a
hazard.
An
all-pole
disconnection
switch,
having
a
contact
separation of
at
least
3mm
in
all
poles,
should
be
connected
to the
fixed
wiring.
When
carrying
out the
piping
connections,
take
care to not
allow air particles infiltrate
into
「
efrigeration
cycle.
Otherwise,
it
can
cause diminished
capacity,
abnormally
high
pressure in
the
refrigeration
cycle,
explosion,
or
injury.
Do
not
modify
the
length
of
the
power
supply
cord,
or
use
an
extension
cord,
and
do
not
share
the
isolated
outlet
with
other
electrical
appliances. Otherwise,
it
can result in
fire
or
electrical
shock.
1