8.2 PCL OUTPUT CONFIRMATION
-
PCL Output
With the TESTIN (149 pin)(TP : TSIN) status of IC602 to be “H”, it is shifted to PCL Output Test mode after reset started.
The clock signal is output from the CLKOUT terminal IC602 (Pin 106)(TP : CKOT) .
The frequency of the clock signal is 47.18592 MHz.
If the clock signal out of the range, the X’tal (X601) should be replaced with new one.