PDP-433PU
74
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Comman
Name
Function
Direct
Validity
UP/DOW
N Validity
Lower
Limit
Upper
Limit
M69
MASK 69
Full mask (sky blue 2_43)
M70
MASK 70
Full mask (light purple 43)
M71
MASK 71
Full mask (yellow)
M72
MASK 72
Full mask (blue 916)
M73
MASK 73
Full mask (reservation)
M74
MASK 74
Full mask (reservation)
MMN
MIRROR MODE NO
Mirror mode OFF (normal display)
MMX
MIRROR MODE X
Right and left reversing display
MMY
MIRROR MODE Y
Top and bottom reversing display
MMZ
MIRROR MODE XY
Top and bottom, right and left reversing display
MTN
PANEL MUTE NO
Release panel mute
MTY
PANEL MUTE YES
Panel mute
NMN
NEGATIVE MODE NO
Negative-positive inversion mode OFF
NMY
NEGATIVE MODE YES
Negative-positive inversion mode ON
PBH
PANEL BLUE HIGH
BLUE HIGH LIGHT adjustment
O
O
000
255
PBL
PANEL BLUE LOW
BLUE LOW LIGHT adjustment
O
O
000
999
PGH
PANEL GREEN HIGH
GREEN HIGH LIGHT adjustment
O
O
000
255
PGL
PANEL GREEN LOW
GREEN LOW LIGHT adjustment
O
O
000
999
PHN
PANEL HIGHT-LIGHT NO
Releasing the W/B highlight maximum mode of the panel
PHY
PANEL HIGHT-LIGHT YES
Setting the W/B highlight of the panel to maximum
PLN
BRIGHT ENHANCE NO
Center brightness correction OFF
PLY
BRIGHT ENHANCE YES
Center brightness correction ON
PMS
PULSE METER SET
Optional setting of the pulse meter
POF
POWER OFF
Standby request
PON
POWER ON
Power ON request
PRH
PANEL RED HIGH
RED HIGH LIGHT adjustment
O
O
000
255
PRL
PANEL RED LOW
RED LOW LIGHT adjustment
O
O
000
999
PCN
PC MODE NO
At the 60Hz input: VIDEO sequence selection
PCY
PC MODE YES
At the 60Hz input: PC sequence selection
PT0
PANEL COLOR TEMP 0
Set each temperature mode to 0 (REF)
PT1
PANEL COLOR TEMP 1
Set each temperature mode to 1 (OFS1)
PT2
PANEL COLOR TEMP 2
Set each temperature mode to 2 (OFS2)
UP0
UP 0
Increasing the adjustment value by 10
UPF
UP FULL
Maximizing the adjustment value
UPn
UP n
Increasing the adjustment value by n
VOF
VOFFSET ADJUST
Vofs adjustment
O
O
000
255
VOL
VOLUME
Volume
O
O
000
060
VSU
VSUS ADJUST
Vsus adjustment
O
O
000
255
XSB
XSUS B
X-SUS-B pulse adjustment
O
O
000
015
XSG
XSUS G
X-SUS-G pulse adjustment
O
O
000
015
YSB
YSUS B
Y-SUS-B pulse adjustment
O
O
000
015
YSG
YSUS G
Y-SUS-G pulse adjustment
O
O
000
015
RS-232C Commands when the Media Receiver is not connected with the PDP