INSTRUCTION MANUAL

General Safety Instructions:

Read the following safety instructions to avoid injury and prevent damage to this product or any
products connected to it. Use this product only as specified.
Only qualified personnel should perform service procedures.

To Avoid Fire or Personal Injury
Connect and Disconnect Properly.

Connect the probe output to the measurement instrument before connecting the probe to the circuit
under test. Disconnect the probe input and the probe ground from the circuit under test before
disconnecting the probe from the measurement Instrument.

Observe All Terminal Ratings.

To avoid fire or shock hazard, observe all rating and markings on the product. Consult the

PT-710 AC/DC current probe

Содержание PT-710

Страница 1: ...m service procedures To Avoid Fire or Personal Injury Connect and Disconnect Properly Connect the probe output to the measurement instrument before connecting the probe to the circuit under test Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement Instrument Observe All Terminal Ratings To avoid fire or shock hazard observe...

Страница 2: ...tatements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER Indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediately ...

Страница 3: ...t needed for AC measurements unless your instrument cannot isolate a DC component if present OFF Range switch Slide the switch from OFF to either the 100 mV A or 10mV A range When either range is selected the probe is turned on and the green battery indicator lights If the indicator does not light see Battery Notes and Battery Installation Battery indicator The green battery indicator lights when ...

Страница 4: ...pe voltage input channel to DC volts and the voltage sensitivity scale to 5m V div 2 Move the OFF Range switch to the 100mV A or 10mV A position to turn on the probe The PT 710 current probe has a green LED power battery indicator If the LED does not light replace the battery or use specified power adaptor 3 Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic ...

Страница 5: ...quency current the momentary peaks may be quite high 7 PT 710 a multifunctional current probe When connecting to a digital meter use the recommended MT 246N BNC to banana adapter Connect the black lead to the meter COM black letters on the meter and the red lead to the VΩ input red letters on the meter 8 To measure only AC current set the meter to measure AC volts 9 To measure DC current set the m...

Страница 6: ...age V Rating Range 10mV A Range 100mV A Max Working voltage V Max floating voltage V DC 100 10 600 600 DC peak AC 100 10 600 600 AC peak 100 10 600 600 AC peak peak 200 20 1200 RMS CAT III 70 7 600 600 RMS CAT II 70 7 600 600 RMS CAT I 70 7 600 600 Voltage and current ratings 8 ...