PIN-M-02 DPMRA01.A Service Manual
Copyright © Pinssar (Aust) Pty Ltd 2019. The PINSSAR logo is a registered trademark of Pinssar Pty Ltd
Page 59 of
96
9.2.2
05-0792 Blower Fault Servicing
9.2.2.1
D
IAGNOSING
B
LOWER
F
AULT
Carry out visual inspection as per Section 8.1.2. The blower can also be diagnosed
through the Red Lion HMI as per Annex A. If the blower fails the test, disconnect Blower
power cable and carry out a continuity test of the blower motor. Replace if the blower
fails the test.
9.2.2.2
R
EPLACING
B
LOWER
Removal
Warning: Set DPM Reader to Safety Control Level 4
Refer to Figure 36
F
IGURE
36
-
R
EMOVING
B
LOWER
1. Using an M5.5 socket remove the 4 nyloc nuts and washers.
2. Using an M5 socket remove the standoff and washer in bottom left corner.
3. Unplug connector.
4. Disconnect hoses.
Installation
Warning: Set DPM Reader to Safety Control Level 4
1. Place blower assembly in position and connect cable and hoses.
Step 1
Step 3