Pinnacle Remington REM-125V-GFA-B Скачать руководство пользователя страница 23

© 2018, Pinnacle Climate Technologies, Inc, 

Manuel de la chaufferette à air forcé au propane 

NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE 

BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE DE COMBUSTIBLE.

11

4

5

9

10

11

12

13

14

22

17

20

19

16

3

23

2

21

1

6

8

7

15

18

VUE ÉCLATÉE

N

o

 de réf.

Description

40-GFA

60V-GFA

125V-GFA

150V-GFA

1

Base

22-501-0003

22-501-0003

22-501-0004

22-501-0004

2

Contrôleur de hauteur

22-512-0006

22-512-0006

22-512-0008

22-512-0008

3

Couvercle de la base

22-508-0003

22-508-0003

22-508-0004

22-508-0004

4

Capuchon d’enveloppe intérieure

22-505-0006

22-505-0010

22-505-0011

22-505-0008

5

Ensemble à supports multiples

22-504-0002

22-504-0002

22-504-0002

22-504-0002

6

Tubage

22-605-0001

22-605-0001

22-605-0002

22-605-0007

7

Buse

22-081-0007

22-081-0014

22-081-0015

22-081-0004

8

Écrou de gicleur

22-518-0001

22-518-0001

22-518-0002

22-518-0002

9

Poignée

70-001-0103

70-001-0103

70-001-0103

70-001-0103

10

Écrou hexagonal de collerette

22-518-0003

22-518-0003

22-518-0003

22-518-0003

11

Ventilateur

22-514-0001

22-514-0001

22-514-0002

22-514-0002

12

Tampon amortisseur

22-509-0001

22-509-0001

22-509-0001

22-509-0001

13

Moteur

22-061-0015

22-061-0015

22-061-0016

22-061-0016

14

Protecteur arrière

22-101-0003

22-101-0003

22-101-0004

22-101-0004

15

Boulon rond

22-503-0002

22-503-0002

22-503-0002

22-503-0002

16

Robinet

22-011-0005

22-011-0017

22-011-0018

22-011-0008

17

Connecteur d’entrée

22-507-0003

22-507-0003

22-507-0003

22-507-0003

18

Module à étincelles

22-604-0005

22-604-0005

22-604-0005

19

Carte de circuits imprimés

22-521-0001

22-521-0002

22-521-0002

22-521-0002

20

Boîtier de la carte de circuits imprimés 22-506-0001

22-506-0001

22-506-0001

22-506-0001

21

Bouton de commande

22-516-0001

22-516-0001

22-516-0001

22-516-0001

22

Cordon électrique

22-131-0001

22-131-0001

22-131-0001

22-131-0001

23

Régulateur

22-041-0004

22-041-0004

22-041-0005

22-041-0005

LISTE DES PIÈCES

Содержание Remington REM-125V-GFA-B

Страница 1: ...BUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS REC OMMENDED BY THESE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AI...

Страница 2: ...the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUG...

Страница 3: ...e square foot 2 800 sq cm opening of out side air for every 100 000 Btu Hr 29 kW heater rating Refer to Ventilation on page 8 for further instructions WHAT TO DO IF THE SMELL OF GAS IS PRESENT DO NOT...

Страница 4: ...eplace it with the proper assembly shown in the parts list prior to using the heater Manifold Minimum and Maximum Inlet Pressure 40 GFA 60V GFA 125V GFA 150V GFA Man 11 279 mm W C 11 279 mm W C 8 3 21...

Страница 5: ...2 6 9 2 5 2 8 3 1 Maximum Operating Hours 11 10 5 22 18 Required Cylinder Lb kg 20 9 20 9 100 45 100 45 Fuel Type Propane Propane Propane Propane Heating Area Ft 2 m2 1000 93 1500 139 3125 290 3800 3...

Страница 6: ...ndard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on vapor withd...

Страница 7: ...N the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbl...

Страница 8: ...40 GFA Shutdown Instructions To Shut Off the Heater 1 Turn gas control knob CLOCKWISE to O OFF position See Figure 5 2 Turn gas supply OFF by turning the LP cylinder valve CLOCKWISE to close 3 Disconn...

Страница 9: ...nd Handling of Petroleum Gases ANSI NFPA 58 latest edition and Natural Gas and Propane Installation Code CSA B149 1 The plastic valve plug or valve cover supplied with the cylinder must be re installe...

Страница 10: ...3 Straighten all fan blades 4 Replace motor assembly Heater will not fire ignite 1 No spark at module 2 Incorrect spark gap 3 Corroded electrode 1 Inspect module wire Re attach or tighten if loose In...

Страница 11: ...0001 22 518 0002 22 518 0002 9 Handle 70 001 0103 70 001 0103 70 001 0103 70 001 0103 10 Flange Hex Nut 22 518 0003 22 518 0003 22 518 0003 22 518 0003 11 Fan 22 514 0001 22 514 0001 22 514 0002 22 5...

Страница 12: ...acle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warran...

Страница 13: ...MAT RIAUX SOLIDES INFLAMMABLES TELS LES MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE LA CHAUFFERETTE COMME RECOMMAND DANS LES PR SENTES INSTRUCTIONS NE JAMAIS UTILISER...

Страница 14: ...le de propane l int rieur DANGER Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou une explosion peuvent survenir et causer des dommages mat riels des blessures...

Страница 15: ...ter pour chaque 29 kWh 100 000 BTU h du r gime nominal de la chaufferette Voir la rubrique Ventilation la page 8 pour plus de d tails QUE FAIRE SI UNE ODEUR DE GAZ EST D TECT E NE PAS tenter d allumer...

Страница 16: ...pi ces avant d utiliser la chaufferette Pressions d entr e collecteur minimum et maximum 40 GFA 60V GFA 125V GFA 150V GFA Collecteur 11 po CE 2 7 kPa 11 po CE 2 7 kPa 8 3 po CE 2 kPa 8 po 1 99 kPa Min...

Страница 17: ...3 1 Nombre maximal d heures de fonctionnement 11 10 5 22 18 Bouteille requise lb kg 20 9 20 9 100 45 100 45 Type de carburant Propane Propane Propane Propane Surface chauff e m 93 139 290 353 Circula...

Страница 18: ...et les entr es de robinets d vacuation pour bouteille de gaz Une soupape de s ret en communication directe avec l espace de vapeur de la bouteille La chaufferette doit fonctionner partir du gaz prove...

Страница 19: ...re en position ferm e OFF ouvrir le robinet de la bouteille de gaz et v rifier qu il n y a pas de fuites avec une solution d eau savonneuse V rification des fuites Pour v rifier qu il n y a pas de fui...

Страница 20: ...tions pour l arr t Pour teindre la chaufferette 1 Tourner le bouton de commande dans le sens HORAIRE la position d arr t O Voir la Figure 5 2 FERMER l alimentation en gaz en tournant le robinet de la...

Страница 21: ...d branch e de la chaufferette REMARQUE L installation et les r parations doivent tre effectu es par du personnel de service qualifi TOUJOURS suivre les proc dures d entretien ad quates Ce qui doit in...

Страница 22: ...urer qu aucune obstruction n entrave le ventilateur 3 Redresser les pales 4 Remplacer le moteur La chaufferette ne peut tre allum e 1 Aucune tincelle au niveau de l allumeur 2 cart de bougie incorrect...

Страница 23: ...8 0002 22 518 0002 9 Poign e 70 001 0103 70 001 0103 70 001 0103 70 001 0103 10 crou hexagonal de collerette 22 518 0003 22 518 0003 22 518 0003 22 518 0003 11 Ventilateur 22 514 0001 22 514 0001 22 5...

Страница 24: ...ate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisation normale ou n est pas d fectue...

Отзывы: