Troubleshooting Guide

Problem

Possible Cause

Solution

Heater fires, but shuts down after a 

short period of time. 

1. Dirty Fuel Filter.

2. Nozzle Dirty.

3. Photocell Dirty.

4. Photocell not installed properly.

5. Photocell Defective .

6. Improper electrical connec-

tion between Circuit Board and 

Photocell.

7. Cooling Fan is obstructed

1. Clean/replace Fuel Filter.

2. Clean/replace Nozzle 

3. Clean/replace Photocell .

4. Adjust Photocell position.

5. Replace Photocell.

6. Check wiring connections (See 

Wiring Diagrams, Page 11).

7. Check to be sure cooling fan is not 

obstructed.

Heater will not operate, or motor 

runs for short time.

1. No Kerosene/ diesel in fuel tank.

2. Corroded Spark Plug or incorrect 

plug gap.

3. Dirty Fuel Filter.

4. Dirty Nozzle.

5. Moisture in Fuel/Fuel Tank.

6. Improper electrical connection 

between Transformer and Circuit 

Board.

7. Transformer Wires not connected to 

Spark Plug.

8. Defective Transformer.

1. Fill tank with fresh Kerosene/ diesel.

2. Clean/replace Spark Plug.

3. Clean/replace Fuel Filter.

4. Clean/replace Nozzle.

5. Rinse out fuel tank with clean fresh 

Kerosene/ diesel.

6. Inspect all electrical connections. 

(See Wiring Diagrams, Page 11).

7. Re-attach Transformer wires to 

Spark Plug.

8. Replace Transformer.

Fan does not operate when heater 

is plugged in and Operating Switch 

is in the “ON” position.

1. Broken electrical connection 

between Circuit Board and motor.

2. Not enough amps available to power 

heater.

1. Inspect all electrical connections on 

Wiring Diagrams (Page 11).

2. Use a new extension cord or try 

another electrical socket.

Heater makes grinding noise.

1. Air in fuel pump.

1. Sound will stop after 3 seconds.  If 

grinding sound continues, add fuel to 

tank.

Heater does not turn on and the 

lamp is not lit.

1. Temperature limit sensor has over-

heated.

2. No electrical power.

3. Fuse break down.

4. Improper electrical connection 

between Temperature Limit Sensor 

and Circuit Board.

1. Push Operating Switch to “OFF” and 

allow heater to cool for 5 minutes. 

Push Operating Switch back to “ON”.

2. Check power cord and extension 

cord to insure of proper connection. 

Test power supply.

3. Check/replace Fuse.

4. Inspect all electrical connections. 

(See Wiring Diagrams, Page 11).

Poor combustion and / or soot 

production.

1. Pump Pressure.

2. Poor fuel quality.

1. Be sure pump pressure is adjusted 

correctly.

2. Be sure Kerosene/ diesel is not old 

or contaminated.

Содержание Master MH-70-SS-A

Страница 1: ...derstand these instructions should operate or service this heater If you need heater info such as an operating manual labels etcetera contact Pinnacle Products International at 800 641 6996 DANGER NOT...

Страница 2: ...tions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosions burns asphyxiation or carbon mono...

Страница 3: ...INDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Страница 4: ...rnational Inc Oil Fired Radiant Heater User s Manual 3 Specifications Features Model MH 70 SS A Rating Btu Hr 70 000 Fuel Consumption G Hr 50 Fuel Tank Capacity G 4 Max Operating Hours 7 2 Volts AC Hz...

Страница 5: ...1 Black Screws 2 Carry Handle Assembly 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 2 2 Insert screws and tighten firmly Tools Needed Phillips Head Screw Drive...

Страница 6: ...ational Inc Oil Fired Radiant Heater User s Manual Step 1 Remove existing screws from shell ring on either side of heater Step 2 Line up holes on heat shield with holes in shell ring Attach with screw...

Страница 7: ...NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue co...

Страница 8: ...e heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the...

Страница 9: ...the original packaging and keep user s manual in an easily accessible place Service DO NOT TAMPER WITH THE UNIT HAVE AN EXPERIENCED SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS We suggest foll...

Страница 10: ...cessary to soak nozzle in clean Kerosene or diesel to help loosen any particles See Figure 9 PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions...

Страница 11: ...Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transformer wires to Spark Plug 8...

Страница 12: ...ATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 2014 Pinnacle Products International Inc Oil Fired Radiant Heater User s Manual 11 Wiring Diagram AC 120V 60Hz AC 125V 3 15A ELECTRIC OUTLET...

Страница 13: ...CTED TO A POWER SOURCE 2014 Pinnacle Products International Inc Oil Fired Radiant Heater User s Manual Exploded View 12 35 33 34 13 31 32 30 29 36 21 14 11 37 10 41 9 7 6 2 3 4 5 40 16 12 17 18 42 8 1...

Страница 14: ...r 75 051 0200 16 Tip over Sensor Wire Assembly 75 051 0260 17 Cooling Motor Assembly 75 047 0250 18 Cooling Fan 75 047 0200 19 Shell 75 011 1010 20 Handle 75 001 0060 21 Shell Insulator 75 011 1100 22...

Страница 15: ...m to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc di...

Страница 16: ...2014 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Отзывы: