Pinnacle Technology PS1X series Скачать руководство пользователя страница 9

 

 

2

 

  ERROR CODE WARNING   

 
 

ERROR

 

‘HLb’ : 

when  the  battery  voltage  is  in  warning  voltage

  (3.1 V

and

 

screen  displays  ‘HLb’ 

words , which means current electricity is about to ran out and can last a very short time .

 

 

ERROR

 

‘LLb’:

  when  the  battery  voltage  is  in  power  off  voltage

  (2.9V, 

scale    will    power  off   

itself automatically when screen displays 

‘LLb’

 words. 

 

When  the  scale  is  in  power  on  status  and  screen  displays 

‘LLb’

  words  accompanied  by  tick 

sound and then power off automatically. which means scale is out of work already and is needed to 
change battery immediately. 

 

3

 

SEALING OPERATION METHOD and ACCELERATION of 
GRAVITY ADJUSTMENT 

Gravity  acceleration  compensation  value  can’t  be  adjusted  directly  after  the  PS1X  price 

computing  scale  adopts  sealing  protection.  If  needs  to  adjust  the  gravity  acceleration,  you  must 

destroy the sealing. 

Our  company  adopts  environmental  label  sealing,  only  needs  to  destroy  the  fragile  label 

sealing to startup the amending mode, do not need to disassemble the cover. 

The  operating  steps  of  adjusting  the  acceleration  of  gravity  A/D  value  and  Zero  full  weight 

learning are as follows:   

3.1

 

Destroy the sealing 

1)

 

Destroy the fragile label sealing   

2)

 

Open the plastic sealing cover. 

3)

 

Only use the sharp-pointed instrument such as pen point to touch the adjustable switch lightly 

can adjust the acceleration of gravity A/D value and zero full weight learning. 

4)

 

What you need to do is breaking the label based on the adjustment and do not need to open case. 

The label sealing must be broke if you want to open the case. Please take the below pictures as 

you references. 

 

 

 

 

 

 
 

Содержание PS1X series

Страница 1: ...PS1X Price Computing Scale Technical Manual Pinnacle Technology Corp...

Страница 2: ......

Страница 3: ...1XD Pole 5 2 ERROR CODE WARNING 6 3 SEALING OPERATION METHOD and ACCELERATION of GRAVITY ADJUSTMENT 6 3 1 Destroy the sealing 6 3 2 The methods of gravity acceleration compensation value adjustment 8...

Страница 4: ...1 1 PS1X EXPLODED VIEWS 1 1 PS1XA Stainless steel platter...

Страница 5: ...2 1 2 PS1XB Stainless steel platter...

Страница 6: ...3 1 3 PS1XC Stainless steel platter...

Страница 7: ...4 1 4 PS1XD Stainless steel platter...

Страница 8: ...5 1 1 PS1XD Pole Stainless platter...

Страница 9: ...r the PS1X price computing scale adopts sealing protection If needs to adjust the gravity acceleration you must destroy the sealing Our company adopts environmental label sealing only needs to destroy...

Страница 10: ...7 Fragile label Screw Adjustable switch Sealing cover Nut Fragile label Screw Adjustable switch Sealing cover...

Страница 11: ...ct please press or key to adjust till the digit is right Automatic adjustment 1 Press the key to start up the scale 2 Take off the platter 3 Destroy the label sealing startup the switch 4 Put the plat...

Страница 12: ...et the range as 30kg 6 Press the key M1 continuously for two times at this time you can hear a long sound beep which means the zero weight learning is successful The weight column will display 0 000 7...

Страница 13: ...10...

Отзывы: