background image

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Radiant Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

Exploded View

12

25

23

24

9

21

22

20

19

26

10

7

28

6

4

3

1

2

27

8

12

13

29

5

16

17

18

14

15

11

30

31

70-SS

Содержание MASTER MH-125-OFR-A

Страница 1: ...Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instruc tions...

Страница 2: ...for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 com...

Страница 3: ...use with an external fuel tank Keep all combustible materials away from this heater Minimum Clearance From Combustibles 70 SS 125 OFR Top 4 ft 125 cm 6 ft 185 cm Sides 4 ft 125 cm 6 ft 185 cm Front 8...

Страница 4: ...EAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 3 Features FUEL PRESSURE GAUGE BEHIND REMOVABLE COVER 70 SS 125 OFR Top Safety Guard Radiant Cone Front Safety Guard Radiant V...

Страница 5: ...iver Figure 1 Figure 2 Attach the handle while still in the box for easier unpacking see Figure 2 Carry Handle 1 Black Screws 2 Step 1 Remove existing screws from shell ring on either side of heater s...

Страница 6: ...attach wheels washers and nuts see Figure 6 2 Place main structure on wheel frame and fasten with long screws provided see Figure 7 3 Attach safety guard to front of heater with screws provided see F...

Страница 7: ...in direct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE...

Страница 8: ...heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the p...

Страница 9: ...ush with water use fresh Kerosene only SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the term...

Страница 10: ...n clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a cotton s...

Страница 11: ...Spark Plug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transf...

Страница 12: ...imate Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 125 OFR 11 Wiring Diagram AC 120V 60Hz AC 250V 3 15A ELECT...

Страница 13: ...es Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 12 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Страница 14: ...0 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit Swit...

Страница 15: ...Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 42...

Страница 16: ...p 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower Mot...

Страница 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Страница 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Отзывы: