Captain 6 Installation Guide
38
Activation of a zone does not cause an alarm
Check the following:
1.
The Zone is not temporarily or permanently bypassed
2.
The zone is programmed for the correct response (siren, relay, etc.)
3.
Power supply is not low – AC or correct battery backup power supply
4.
Detectors are installed correctly and not malfunctioning
7.
PARTITIONS
CAPTAIN 6 can be configured into 2 partitions with the following settings:
1.
Each zone and each user can be assigned to one of the 2 partitions or both.
2.
Each partition can have a different subscriber (account) ID.
3.
All keypads connected to the system show the same display, regardless their partition.
7.1
Additional information
To assign zones to partitions: see section 5.1.3
To program subscriber (account) ID: see section 5.2.1
To assign users to partitions: see section 5.6.1
See “CAPTAIN 6 User Guide for information on keypads display and partitions.