Rev. A - Supplement to P/N 4410067 Rev. C (Dec-2002)
HUNTER-PRO Intruder Alarm
H/W Rev E & F/W v2.1
Installation and Programming
Manual supplement
New Hardware Revision: E
The new hardware has the following changes added to it:
1
A Terminal Block was added for Audio Out. This is for future use.
When connecting MIC-100 or VU-20, use the CONTROL and IN terminals as
described in the HUNTER-PRO Installation Manual.
The writing on the PCB was also changed. See the following table for reference to
earlier HUNTER-PRO revisions:
PCB Writing
Earlier Revisions Revision E
CONT CONTROL
AUD IN
2
A new Jumper was added to control a siren’s power source: JP6.
The following table describes the new jumper functionality:
Jumper
Position
Siren Power
Source
Notes
1-2
Unregulated
When using HUNTER-PRO tones to drive a speaker
2-3
Battery
When using Hunter Pro with self activating bell
NOTE:
These modes are ONLY applicable when JP5 position is: 2-3