SDD ES PROFINET
Operating Manual SDD ES PROFINET
1003826-EN-01
18
Reset Passwords
Option
Meaning
Confirm Reset
No
Yes
The password for the Settings area can be reset to
the password supplied when delivered.
}
Select Yes to reset the password
}
Select No to retain the password
Lock Autoinit
Option
Meaning
Options for the control of the guard locking activa-
tion.
The setting can also be made via a fieldbus re-
gister.
Set to No
Guard locking activation up to the first command via
fieldbus using safety outputs of the safety control
system
Set to Yes
Guard locking activation only via Safety Device Dia-
gnostics
Device History menu
Device History
Option
Value range
Meaning
Status
Display of message number. The message number
is incremented up to 150. Then the oldest message
is overwritten. All message numbers are deleted by
switching off the supply voltage.
Device
1-16
Number of device
Safety Gate
Actuator is within the response range
Actuator is not within the response range
in sec
Time at which the safety gate was opened (seconds
since power-on)
Lock
Guard locking activation
Guard locking activation