Installation
Operating Manual PSEN sg2c-5CCLLE
1004172-EN-02
| 29
}
Align actuator guide plate and safety switch. Please note the distance between the
handle unit and the safety switch (see chapter
Adjustment [
39]
).
}
Fix actuator guide plate and safety switch with M5 - DIN EN ISO 4762 - socket head cap
screws (hexagon socket, e.g.: Bossard: BN3 (without shaft), galvanised blue, torque set-
ting Ma = 5 Nm). Use washer M5 - DIN125A (e.g.: Bossard: BN 715, galvanised blue, di-
mension: 10 x 5.3 x 1) for this.
The fixing screws on the safety switch are located under the cover of the escape release.
Use an appropriate screw adhesive (e.g. Loctite 2700) to protect the socket head cap
screws from working loose.
WARNING!
Risk of manipulation of the safety device if the actuator guide plate is
not secured permanently!
If the actuator guide plate is not secured permanently, there is a risk that the
safety function will be defeated through manipulation. Depending on the ap-
plication, serious injury or death may result.
– If the actuator guide plate is installed using only the unprotected
screws [1] accessible from the side, then one-way screws must be
used for manipulation protection.
– If the screws used under the bolt tongue [2] are protected against
manipulation, then this is not necessary.
[1]
[2]