PSEN b5
Operating Manual PSEN b5
1002471EN03
7
Please note:
}
Do not use the safety switch and actuator as a limit stop.
}
Always test the function with one of the approved evaluation devices.
Intended use
The bolt is used as a mechanical guard locking device in accordance with EN ISO 121002
and EN 1088. It is designed for use as a mechanical interlock in conjunction with a safety
switch of type
}
PSEN cs3.1
}
PSEN cs4.1
}
PSEN cs4.2
}
PSEN me1S
}
PSEN me1.2S
}
PSEN me1.21S
}
PSEN me1M
Possible combinations of safety switches
The bolt can be used
}
only with one safety switch PSEN cs
}
only with one safety switch PSEN me
}
or with a safety switch PSEN cs in conjunction with a safety switch PSEN me
A padlock can also be used to protect the bolt from unauthorised opening and closing.
The bolt may
not
be used on its own as a safety component to avoid hazardous plant or
machine statuses.
INFORMATION
If PLe is required, for gate monitoring for example, a safety switch PSEN cs
can also be installed in addition to a safety switch PSEN me.
Installation
CAUTION!
Do not install the bolt until you have read and understood the operating in
structions for the safety switches PSEN cs or PSEN me! Pay particular at
tention to the information on operating distances and installation. Make sure
that you comply with the technical details!