PSEN ma1.3b-24 VA
Operating Manual PSEN ma1.3b-24 VA
22227-EN-03
| 13
brown
white
blue
black
3
5
2
4
6
1
S21
S22
S11
S12
PNOZ s3
PSENmag
Non-Ex area Ex area
Auxiliary contact with LED
The auxiliary contact and the LED indicate the status of the safety contacts.
Actuator in the response range
Safety contacts and auxili-
ary contact
LED
Yes
Closed
lights
No
Open
Off
1
2
3
4
5+
6
24 V
GND
PSENmag
1
2
3
4
5+
6
24 V
PLC
PSENmag
Connecting the auxiliary contact to an eval-
uation device
Connecting the auxiliary contact to a PLC
Installation
}
The unit can be installed in any position. Safety switches and actuators must be installed
so that the sensing face of the safety switch is exactly opposite the sensing face of the
actuator.
}
If possible, do not install the safety switch and actuator on to ferromagnetic material.
Changes to the operating distances are to be expected.
}
Make sure that the earthing is in accordance with the specifications in EN 60079-14.