PSEN ma1.3-22 M12/8 VA
Operating Manual PSEN ma1.3-22 M12/8 VA
1004511-EN-02
7
For your safety
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If spare actuators are used, these must be installed as described in
.
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
}
Do not remove the connector's protective cap until you are just about to connect the
unit. This will prevent potential contamination.
Unit features
}
The actuator PSEN ma1.3-08 VA belongs to the safety switch.
}
Coded actuator
}
Safety switch with 8-pin M12 male connector
}
Use with temperatures over 80 °C
}
2 safety contacts (reed contacts - N/O)
}
1 auxiliary contact (N/O)
}
Design: cylindrical with threaded sleeve
–
Safety switch M12
–
Actuator M12: PSEN ma1.3-08 VA
}
Operation Magnetic
}
Switching voltage 24 VDC
}
Series connection via PSEN ix1 interface
}
Switch and actuator from stainless steel
Function description
Application in series connections
Operate the PSEN ma1.3-22 M12/8 VA in conjunction with the following components:
}
Actuator PSEN ma1.3-08 VA (see
}
interface PSEN ix1 (see
) and
}
a connected evaluation device (see
Requirements and connection to evaluation
devices [