PSEN ma1.3-22 M12/8 VA
Operating Manual PSEN ma1.3-22 M12/8 VA
1004511-EN-02
10
}
Depending on which evaluation device is used, the overall cable resistance must be
checked; before commissioning it may also be necessary to check the cross circuit de-
tection function.
Perform the checks as described in the operating manual for the evaluation device.
}
The supply voltage for the auxiliary contact must be provided via a Class III power sup-
ply.
}
The safety contacts are not short circuit-proof.
}
UL requirement: the supply voltage must be provided via a Class 2 power supply.
Pin assignment
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory
The safety switch is shown in an unoperated condition.
Assignment of the 8-pin
M12 male connector
6
3
5
4
1
NC
2
7
8
NC
Pink
Green
White
Yellow
Brown
Blue
Red
Grey
NOTICE
The auxiliary contact (pin 2, pin 7)
– can be connected in series
– may
not
be used for safety circuits
Requirements and connection to evaluation devices
For use of PSEN ma1.3-22 M12/8 VA in accordance with DIN EN 60947-5-3 an evaluation
device must be connected.
Connect the PSEN ma1.3-22 M12/8 VA
}
either
with a certified Pilz evaluation device
}
or
with an evaluation device with defined properties