Unit features
}
Transponder technology for presence detection
}
Pilz coding type: Coded
}
Dual-channel operation
}
2 safety inputs for series connection of multiple safety switches
}
2 safety outputs
}
Safety Device Diagnostics (SDD)
Safety Device Diagnostics can be used to poll sensor information, to perform actions
and to read configuration parameters
}
Diagnostic input for Y1 for Safety Device Diagnostics (SDD)
}
Signal output/diagnostic output Y32 for Safety Device Diagnostics
}
Magnetic latching with permanent magnet, (holding force 30 N)
}
LED display for:
– State of actuator detection
– State of the inputs
– Supply voltage/fault
}
1 actuation direction with 3 approach directions (see
Explanation of markings [
11]
)
– Square marking
The guaranteed safe operating distances for the specified selections only apply when
the actuator approaches the switch vertically. With other approach directions, the oper-
ating distances may partly be considerably larger.
Function description
The safety outputs may have a high or low signal, depending on the position of the actuator
and the signal status of the safety inputs.
Electrical states of the safety inputs and outputs (when switch is ready for operation:
DEVICE LED is green):
Actuator in
the re-
sponse
range
Safety input
S11
Safety input
S21
Safety out-
put 12
Safety out-
put 22
Signal out-
put Y32
(without use
of the SDD)
Yes
High
High
High
High
High
Yes
Low
Low
Low
Low
High
No
x
x
Low
Low
Low
Yes
High
Low
High
Low
High
Yes
Low
High
Low
High
High
x: High or low signal