Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-7
7.6
Diagnostics
7
Operation
7.6
Diagnostics
7600
Diagnostics
7-
Diagnose BAWS
For monitoring and diagnostics of the operating mode selector switch
4 back-lit buttons and 4 signal outputs are available. The outputs report
status information, which is divided into the following information class-
es:
Selected operating mode
Set authorisation
Messages (e.g. user error and fault)
The status information can be evaluated through a control system.
The back-lit buttons indicate the operating mode selected on the oper-
ating mode selector switch.
7.6.1
Signal outputs for status information
Signal outputs for status information
7-
Meldeausgänge Statusinformation BAWS
The status information indicates the actions performed by the operator.
These actions are: actuator connected, actuator removed and operating
mode selected.
NOTICE
If OM is selected (SI3:0=8h ... Bh) information remains active
indefinitely. All other information stays active for just 200 ms.
After that time the selected operating mode is again displayed.
Status information
SI 3 (MSB)
SI 2
SI 1
SI 0 (LSB)
SI3:0= [hex]
Reserve
0
0
0
0
0h
Reserve
0
0
0
1
1h
Reserve
0
0
1
0
2h
Reserve
0
0
1
1
3h
Key Mode 1 - connected
0
1
0
0
4h
Key Mode 2 - connected
0
1
0
1
5h
Key Mode 3 - connected
0
1
1
0
6h
Key Mode 4 - connected
0
1
1
1
7h
OM1 selected
1
0
0
0
8h
OM2 selected
1
0
0
1
9h
OM3 selected
1
0
1
0
Ah
OM4 selected
1
0
1
1
Bh
No authorisation
1
1
0
0
Ch