background image

PIT en1.0/PIT en1.1

Operating Manual PIT en1.0/PIT en1.1
1002172-EN-09

| 8

Connection to evaluation device

Connection to PNOZ X, PNOZsigma, PNOZelog

PNOZ e1p

PNOZ e1.1p

PNOZ e1vp

PNOZ e6.1p

PNOZ e6vp

PNOZ s3

PNOZ s4

PNOZ s5

PNOZ X2C

PNOZ X2

PNOZ X2.7P

PNOZ X2.8P

PNOZ X2.9P

white

brown

green

yellow

PNOZ e5.11p

white

brown

green

yellow

PNOZ X3.1

PNOZ X3P

PNOZ X3

PNOZ X3.10P

PNOZ XV2

PNOZ XV2P

PNOZ XV3

PNOZ XV3P

white

brown

green

yellow

Connection to PDP67 F 8DI ION

The connection is made via the adapter PSEN mag ad (see operating manual PSEN adapt
PSS67/PDP67 4p).

Connection to PNOZmulti

Safety gate with switch type 3

I0, I1: Inputs

T0, T1: Test pulse outputs

white

brown

green

yellow

Connection to PSS with or without SafetyBUS p

Safety gate with switch type 3

I0, I1: Inputs

O16, O17: Test pulse outputs

white

brown

green

yellow

We recommend that you use the standard function block SB064 or SB066 for connecting to
a PSS.

Содержание PIT en1.0

Страница 1: ...PIT en1 0 PIT en1 1 Operating Manual 1002172 EN 09 Control and signal devices...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...al 6 For your safety 6 Unit features 6 Block diagram terminal configuration 7 Function description 7 Wiring 7 Connection to evaluation device 8 Connection to PNOZ X PNOZsigma PNOZelog 8 Connection to...

Страница 4: ...that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates pr...

Страница 5: ...vices described under Connection to evaluation device 8 The enabling switch may not be used on its own to switch on a potentially hazardous con dition The enabling switch may not be used in place of o...

Страница 6: ...alist standards applicable to the specific application Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it...

Страница 7: ...n Operated as far as end stop no enabling signal off panic function This guarantees that the enabling signal is interrupted not only when the switch is released but also when it is fully operated If t...

Страница 8: ...3 PNOZ X3 10P PNOZ XV2 PNOZ XV2P PNOZ XV3 PNOZ XV3P white brown green yellow Connection to PDP67 F 8DI ION The connection is made via the adapter PSEN mag ad see operating manual PSEN adapt PSS67 PDP6...

Страница 9: ...PIT en1 0 PIT en1 1 1002172 EN 09 9 Dimensions Enabling switch Dimensions with PIT en1 0p 5m s as an example The dimensions of the pushbutton hous ing and the cable length are identical with all varia...

Страница 10: ...V 30 V 30 V Max current 0 7 A 0 7 A 0 7 A DC12 at 30 V 30 V 30 V Max current 1 A 1 A 1 A Environmental data 401110 401111 401112 Ambient temperature Temperature range 0 50 C 0 50 C 0 50 C Storage tem...

Страница 11: ...nual PIT en1 0 PIT en1 1 1002172 EN 09 11 Mechanical data 401110 401111 401112 Dimensions Height 125 mm 125 mm 125 mm Width 45 mm 45 mm 45 mm Depth 45 mm 45 mm 45 mm Diameter of pushbutton 45 mm 45 mm...

Страница 12: ...type Features Order no PIT en1 0p 5m s Cable 5 m with 5 pin M12 angled connector 401 110 PIT en1 0a 5m s 6 core open ended cable 5 m 401 111 PIT en1 1a 5m s 6 core open ended coiled cable 5 m 401 112...

Страница 13: ...tyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dep...

Отзывы: