Two-hand control unit
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
Up to PL e of EN ISO 13849-1
P2HZ X1.10P
NSG-D-2-324-2009-09
Preparing for operation
Betriebsbereitschaft herstellen
`
Supply voltage
`
Input circuit
`
Feedback loop
`
Semiconductor output
`
Key
Supply voltage
AC
DC
A1
L1
N
A2
A1
L+
A2
L-
Input circuit
Single-channel
Dual-channel
Two-hand button
with detection of shorts across contacts
S22
S21
S12
S11
S13
S23
S1
S2
Feedback loop
Contacts from external contactors
K5 K6
K5
L1
N
K6
Y1
13 (23, 33)
Y2
14 (24, 34)
Y31
Y32
24 V DC
SPS Input
0 V
Y30
Y35
SPS Input
S1/S2
Two-hand button