PNOZ po3.3p
Operating Manual PNOZ po3.3p
20678-EN-07
14
Relay outputs
Utilisation category of safety contacts
AC1 at
500 V
Min. current
0,21 A
Max. current
8 A
Max. power
4000 VA
AC1 at
400 V
Min. current
0,21 A
Max. current
10 A
Max. power
4000 VA
AC1 at
240 V
Min. current
0,21 A
Max. current
16 A
Max. power
4000 VA
AC3 at
500 V
Max. power
4 kW
AC3 at
400 V
Max. power
5,5 kW
AC3 at
240 V
Max. power
3 kW
DC1 at
24 V
Min. current
0,21 A
Max. current
16 A
Max. power
400 W
Utilisation category
In accordance with the standard
EN 60947-5-1
Utilisation category of safety contacts
AC15 at
230 V
Max. current
6 A
DC13 (6 cycles/min) at
24 V
Max. current
1,5 A
Utilisation category in accordance with UL
Voltage
240 V AC G. P.
With current
12 A
External contact fuse protection, safety contacts
In accordance with the standard
EN 60947-5-1
Blow-out fuse, quick
16 A
Blow-out fuse, slow
16 A
Blow-out fuse, gG
16 A
Circuit breaker 24V AC/DC, characteristic B/C
16 A
Contact material
AgCdO
Conventional thermal current while loading sev-
eral contacts
Ith per contact at UB DC; AC1: 240 V, DC1: 24 V
Conv. therm. current with 1 contact
16 A
Conv. therm. current with 2 contacts
16 A
Conv. therm. current with 3 contacts
12 A