Operating Manual PNOZ s22
22170-EN-04

7

Safety regulations

Safety assessment

Before using a device it is necessary to perform a safety assessment in accordance with
the Machinery Directive.

Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.

Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.

A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.

It is the company’s responsibility only to employ personnel who

}

Are familiar with the basic regulations concerning health and safety / accident preven-
tion,

}

Have read and understood the information provided in the section entitled Safety

}

Have a good knowledge of the generic and specialist standards applicable to the spe-
cific application.

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended,

}

Damage can be attributed to not having followed the guidelines in the manual,

}

Operating personnel are not suitably qualified,

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

Disposal

}

In safety-related applications, please comply with the mission time T

M

 in the safety-re-

lated characteristic data.

}

When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).

Содержание 750132

Страница 1: ...PNOZ s22 Operating Manual 22170 EN 04 Safety relays...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...7 Use of qualified personnel 7 Warranty and liability 7 Disposal 7 For your safety 8 Unit features 8 Safety features 8 Block diagram terminal configuration 9 Function description 9 Installation 9 Wiri...

Страница 4: ...Contents Operating Manual PNOZ s22 22170 EN 04 4 Permitted operating height 19 Remove plug in terminals 20 Order reference 20 EC declaration of conformity 20...

Страница 5: ...ly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures...

Страница 6: ...elated characteristic values stated under safety related character istic data can only be achieved if the base unit also exhibits these values The following is deemed improper use in particular Any co...

Страница 7: ...s systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibility onl...

Страница 8: ...controlled separately LED indicator for Input state of channel Ext 1 O0 Input state of channel Ext 2 O1 Plug in connection terminals either spring loaded terminal or screw terminal See order referenc...

Страница 9: ...rately Installation Connect the contact expansion block to the PNOZ s30 or base unit PNOZ mm0 1p PNOZ mm0 2p Connect the contact expansion block using the connector supplied Control cabinet installati...

Страница 10: ...t contacts see Technical details 12 Use copper wire that can withstand 60 75 C Sufficient fuse protection must be provided on all output contacts with capacitive and in ductive loads Ensure the wiring...

Страница 11: ...safety contacts switch off output and start the device again so that the internal diagnostics can check that the safety contacts open correctly for SIL CL 3 PL e at least 1x per month for SIL CL 2 PL...

Страница 12: ...sted Electrical data 750132 751132 Supply voltage Voltage tolerance 15 20 15 20 Supply voltage Voltage 24 V 24 V Kind DC DC Power consumption 1 5 W 1 5 W Duty cycle 100 100 Relay outputs 750132 751132...

Страница 13: ...A 1500 VA DC1 at 24 V 24 V Min current 0 01 A 0 01 A Max current 6 A 6 A Max power 150 W 150 W Utilisation category In accordance with the standard EN 60947 5 1 EN 60947 5 1 Utilisation category of sa...

Страница 14: ...rmal current while loading several contacts 750132 751132 Ith per contact at UB DC AC1 240 V DC1 24 V Conv therm current with 1 con tact 6 A 6 A Conv therm current with 2 con tacts 5 A 5 A Conv therm...

Страница 15: ...cycles Material Bottom PC PC Front PC PC Top PC PC Connection type Screw terminal Spring loaded terminal Mounting type plug in plug in Conductor cross section with screw terminals 1 core flexible 0 2...

Страница 16: ...1 6 A 2 6 A 3 5 A Safety characteristic data Operating Mode EN ISO 13849 1 2015 PL EN ISO 13849 1 2015 Category EN 62061 SIL CL EN 62061 PFHD 1 h IEC 61511 SIL IEC 61511 PFD EN ISO 13849 1 2015 TM yea...

Страница 17: ...ut If the service life graphs are not accessible the stated PFH value can be used irrespective of the switching frequency and the load as the PFH value already considers the relay s B10d value as well...

Страница 18: ...e life 1 000 000 cycles Provided the application to be implemented requires fewer than 1 000 000 cycles the PFH value see Technical details 12 can be used in the calculation To increase the service li...

Страница 19: ...e category Max rated impulse withstand voltage 3000 m 150 V II 2 5 kV 100 V III 2 5 kV 4000 m 150 V II 2 5 kV 100 V III 2 5 kV 5000 m 150 V II 2 5 kV 100 V III 2 5 kV Reduction of rated insulation vol...

Страница 20: ...nection type Order No PNOZ s22 24 VDC Screw terminals 750 132 PNOZ s22 C 24 VDC Spring loaded terminals 751 132 EC declaration of conformity This product these products meet the requirements of the di...

Страница 21: ...yNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depe...

Отзывы: