PSEN opII mirror column
Operating Manual PSEN opII mirror column
1004629-EN-02
13
[1]
[4]
[3]
[2]
[6]
[7]
[8]
[9]
[9]
[5]
[5]
[5]
Legend
[1] Transmitter
[2] First deviating mirror
[3] Second deviating mirror
[4] Receiver
[5] Path of light beam
[6] Distance between two deviating mirrors
[7] Distance from the transmitter to the first deviating mirror
[8] Distance from the second deviating mirror to the receiver
[9] Angle between transmitter/receiver and deviating mirror
5. Make sure that there are no opaque objects between the safety light curtain's transmit-
ter/receiver and the mirror column.
The full light beam from the safety light curtain's transmitter must be able to strike the
deviating mirror.
The full light beam reflected by the deviating mirror must be able to strike the safety
light curtain's receiver.
Even a small displacement of the PSEN opII mirror column can cause a misalignment
and a malfunction of the safety light curtain.
6. Drill holes in the floor for the floor anchors and insert the floor anchors.