PSEN op4H-SL Series
Operating Manual PSEN op4H-SL Series
1004305-EN-01
21
Cascading with master/slave units arranged at right angles (with C or L-brackets)
When safety light grids are arranged at right angles there is a reduced resolution of 18 mm
at the ends of the safety light grid.
Use C-brackets or L-brackets when safety light grids are arranged at right angles.
[1]
Legend
[1] C or L-brackets
Installation
Please note:
}
The optical surfaces of the transmitter and receiver must be parallel to each other and
oriented opposite to each other.
}
The connection sides of the transmitter and receiver must be on the same side and at
the same height (see diagram).