SDD ES PROFIBUS
Operating Manual SDD ES PROFIBUS
1003825-EN-06
| 18
Device n/x
Option
Value range
Meaning
xxx
Max. 16 charac-
ters (letters,
numbers and
special charac-
ters)
Equipment identifier (on a fieldbus module with web
server)
Coded Switch
e.g. coded switch Information about device type
(*1)
Ready
/
Status of safety device
Ready
Not available
Safety Gate
/
Status of safety gate
Actuator within the response range
Actuator not within the response range
Lock
/
Status of guard locking
activated
deactivated
OSSD1
/
Status of OSSD1
ON state
OFF state
OSSD2
/
Status of OSSD2
ON state
OFF state
INPUT1
/
Status Input 1
INPUT2
/
Status Input 2
Coding
C, F, U
Pilz coding type
(*1)
C = coded, F = fully coded, U = uniquely fully coded
TeachIn free
1-8
Number of teach-in processes remaining
(*1)
Temp °C
Temperature of a safety device in °C. The temper-
ature of one safety device is updated every two
minutes; with 16 safety devices, for example, the
temperature of the first safety device is updated
every 32 minutes.
Act.#
Actuator short name
Ident#
Material number of safety device
(*1)
SN#
Serial number of safety device
(*1)
(*1)
Value on restart