Pilz 540132 Скачать руководство пользователя страница 1

SDD ES PROFIBUS

Operating Manual-1003825-EN-06

}

PSEN sensor technology

Содержание 540132

Страница 1: ...SDD ES PROFIBUS Operating Manual 1003825 EN 06 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...apply 8 Use of qualified personnel 9 Warranty and liability 9 Disposal 9 Function description 10 Operation 10 Data structure 10 Block diagram 11 Installation 11 Commissioning 12 Wiring 12 General wir...

Страница 4: ...Contents Operating Manual SDD ES PROFIBUS 1003825 EN 06 4 Dimensions in mm 19 Technical details 20 Order reference 23 Product 23 Accessories 23 EC declaration of conformity 23...

Страница 5: ...s particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventi...

Страница 6: ...is an active subscriber Master of Safety Device Diagnostics Backlit display LEDs for Supply voltage Fieldbus interface Safety states and diagnostic information for the safety devices Error Multifunct...

Страница 7: ...interface X4 TX Outgoing communication to the safety devices RX Incoming communication from the safety devices 1 6 Configurable inputs outputs for connecting signal inputs outputs from additional dev...

Страница 8: ...nical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details see Technical details 20 NOTICE EMC compl...

Страница 9: ...ibility only to employ personnel who Are familiar with the basic regulations concerning health and safety accident prevention Have read and understood the information provided in the section entitled...

Страница 10: ...f the control of safety devices with guard locking control of the guard locking via SDD can be switched on and off on PROFINET EtherNET IP and ETH using Autoinit Communication with connected control s...

Страница 11: ...attach it to a DIN rail 35 mm When installed vertically Secure the unit by using a fixing element e g retaining bracket or end angle Push the device upwards or downwards before lifting it from the DI...

Страница 12: ...ations for extra low voltages with protective elec trical separation SELV PELV Connecting the supply voltage Connect the supply voltage to the fieldbus moduleSDD ES PROFIBUS 24 V terminal 24 VDC 0 V t...

Страница 13: ...Config 2 Make sure that SSA ON is selected 3 Switch to the Restart menu and press the multifunction switch to confirm the restart of the SDD ES PROFIBUS System structure PROFIBUS DP Slave 1 PROFIBUS...

Страница 14: ...ge see Technical details 20 green Supply voltage is present Profibus Bus connection is not available green Bus connection available Devices All connected devices are enabled green At least one connect...

Страница 15: ...y voltage 2 Display of menu levels 3 Software version 4 Display of possible actions at menu level Rotate multifunction switch menu item up or down Press multifunction switch back one level Operate men...

Страница 16: ...ent Message on the change of state of a safety device Menu settings GPIO Mapping Value range Meaning PLC Value is set by control system 1 16 1 16 represents a connected safety device If the actuator e...

Страница 17: ...16 Number of device Safety Gate Actuator is within the response range Actuator is not within the response range in sec Time at which the safety gate was opened seconds since power on Lock Guard lockin...

Страница 18: ...ock Status of guard locking activated deactivated OSSD1 Status of OSSD1 ON state OFF state OSSD2 Status of OSSD2 ON state OFF state INPUT1 Status Input 1 INPUT2 Status Input 2 Coding C F U Pilz coding...

Страница 19: ...Event Nr x Display of consecutive event numbers event num ber is incremented up to 150 and then the oldest number is overwritten Device x Number of device Message x Display of a message or message nu...

Страница 20: ...d Electrical data Supply voltage for Module supply Voltage 24 V Kind DC Output of external power supply DC 2 W Status indicator Display LED Inputs Number 6 Semiconductor outputs Number 6 Short circuit...

Страница 21: ...C Climatic suitability In accordance with the standard EN 60068 2 30 EN 60068 2 78 Humidity 90 r h at 55 C Condensation during operation Not permitted Max operating height above sea level 2000 m EMC E...

Страница 22: ...Front PC Top PC Connection type Spring loaded terminal plug in screw terminal plug in Conductor cross section with screw terminals 1 core flexible 0 25 2 5 mm 24 12 AWG Dimensions Height 115 mm Width...

Страница 23: ...12 8 pin socket M12 8 pin pin M8 4 pin pin 540 331 PSEN Y junction M8 M12 M12 PIGTAIL M12 8 pin socket M12 8 pin pin M8 8 pin socket 540 337 PSEN Y junction M12 M12 M12 PIGTAIL M12 8 pin socket M12 8...

Страница 24: ...XXX en 0X 2021 01 Printed in Germany Pilz GmbH Co KG 2021 Support Technical support is available from Pilz round the clock Pilz develops environmentally friendly products using ecological materials an...

Отзывы: