PSEN ma1.3p-22
Operating Manual PSEN ma1.3p-22
22148-EN-05
| 17
}
The assured operating distance S
ao
and the assured release distance S
ar
must be tested
under real conditions.
}
Do not apply any installation tools (e.g. Pliers) on the surfaces of the switch.
}
If possible, do not install the safety switch and actuator on to ferromagnetic material.
Changes to the operating distances are to be expected.
}
Protect the safety switch and actuator from UV light or direct sunlight.
}
The protection type (see
Technical details [
21]
) can only be achieved by using the
Pilz connection leads available as an accessory.
Installation of safety switch
Sensing face
Slide the switch through the hole in the
mounting surface with the sensing face to-
wards the actuator.
Attach the switch using 2 M12
hexagonal nuts with special threads.
Note the max. torque setting (see
Tech-
nical details [
21]
).
Installation with actuator PSEN ma1.3-08
Sensing face
Slide the actuator through the hole in the
mounting surface with the sensing face to-
wards the safety switch.