Pilz 506 410 Скачать руководство пользователя страница 19

PSEN ma1.1p-12

Operating Manual PSEN ma1.1p-12
22190-EN-04

| 19

Accessories

Cable

Product type

Connection 1

Connection 2

Length

Order no.

PSEN Kabel Winkel/cable
angleplug 2m

Female connector, M8
angled, 4-pin

Open cable end

2 m

533 110

PSEN Kabel Gerade /cable
straightplug2m

Female connector, M8
straight, 4-pin

2 m

533 111

PSEN Kabel Winkel/cable
angleplug 5m

Female connector, M8
angled, 4-pin

5 m

533 120

PSEN Kabel Gerade/cable
straightplug 5m

Female connector, M8
straight, 4-pin

5 m

533 121

PSEN Kabel Winkel/cable
angleplug 10m

Female connector, M8
angled, 4-pin

10 m

533 130

PSEN Kabel Gerade /cable
straightplug10m

Female connector, M8
straight, 4-pin

10 m

533 131

PSEN Kabel Winkel/cable
angleplug 3m

Female connector, M8
angled, 4-pin

30 m

533 140

PSEN Kabel Gerade /cable
straightplug30m

Female connector, M8
straight, 4-pin

30 m

533 141

PSS67 Cable M8sf M12sm Female connector, M8

straight, 4-pin

Male connector M12
straight

3 m

380 200

5 m

380 201

10 m

380 202

30 m

380 203

PSS67 Cable M8af M12sm Female connector M8

angled, 4-pin

3 m

380 204

5 m

380 205

10 m

380 206

30 m

380 207

Adapter, spacer, screws

Product type

Features

Order no.

PSEN ma adapter

Adapter for connecting the safety switch to PSS67 and PDP67

380 300

PSEN spacer

Spacer

534 310

PSEN screw M4x16 10pcs

Screws made of high-grade steel with one-way slot

540 310

Содержание 506 410

Страница 1: ...PSEN ma1 1p 12 Operating Manual 22190 EN 04 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...l 6 Warranty and liability 6 Disposal 6 For your safety 7 Unit features 7 Function description 7 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requirem...

Страница 4: ...particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive...

Страница 5: ...see Requirements and connection to evaluation devices 10 The following is deemed improper use in particular Any component technical or electrical modification to the product Use of the product outsid...

Страница 6: ...devices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibil...

Страница 7: ...ove the connector s protective cap until you are just about to connect the unit This will prevent potential contamination Unit features The actuator PSEN 1 1 10 belongs to the safety switch Coded actu...

Страница 8: ...3 4 Actuator Safety switch Magnet Operating distances Sao So Sr Sar mm Somin On Off Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independe...

Страница 9: ...0 2 5 3 0 1 0 2 5 2 0 2 0 1 5 0 5 1 5 2 5 2 0 1 5 1 0 0 5 2 0 2 5 1 5 1 0 2 5 1 5 0 5 3 0 0 5 Wiring Information given in the Technical details 16 must be followed Calculation of the max cable length...

Страница 10: ...on lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition Assignment of the 4 pin con nector 1 2 3 4 1 2 3 4 white brown blue black Re...

Страница 11: ...in the operating manual for the selected evaluation device Defined properties of evaluation devices 2 channel with feasibility monitoring Open circuit monitoring of the safety switch is performed Inp...

Страница 12: ...23 24 21 22 31 33 34 32 41 43 44 42 A1 A2 1 2 3 4 11 12 14 13 1 2 3 4 21 22 24 23 1 2 3 4 31 33 34 32 1 2 3 4 41 43 44 42 24 V I0 0 I0 1 I0 2 I0 3 24 V 0 V PSEN ix1 PLC PSENmag Evaluation device Input...

Страница 13: ...nnection to Pilz evaluation devices I0 I1 PNOZmulti PSENmag 3 1 2 4 T1 T0 PSEN ix1 3 1 2 4 11 12 13 14 brown white blue black Legend I0 Input OSSD I1 Input OSSD T1 T2 Test pulse outputs brown white bl...

Страница 14: ...nuts made of non magnetic material e g brass or stainless steel Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch an...

Страница 15: ...he operating distances are to be expected In this case use the spacer see Order reference 19 Safety switches and actuators should only be secured using M4 screws with a flat head e g M4 cheese head or...

Страница 16: ...ISO 14119 4 Classification in accordance with EN 60947 5 3 PDDB Electrical data Supply voltage Voltage 24 V Kind DC Voltage tolerance 20 20 Supply voltage Max current 700 mA Max switching frequency 1...

Страница 17: ...1 PSEN 1 1 10 Typ Hysteresis 4 mm Operating distances Assured operating distance Sao 3 mm Min operating distance Somin 0 5 mm Typical operating distance So 5 mm Assured release distance Sar 19 mm Typ...

Страница 18: ...vel for your plant machine B10d in accordance with EN ISO 13849 1 2015 and EN 62061 TM year in accordance with EN ISO 13849 1 2015 10 000 000 20 Order reference System Product type Features Connection...

Страница 19: ...10 m 533 130 PSEN Kabel Gerade cable straightplug10m Female connector M8 straight 4 pin 10 m 533 131 PSEN Kabel Winkel cable angleplug 3m Female connector M8 angled 4 pin 30 m 533 140 PSEN Kabel Gerad...

Страница 20: ...67 F 8DI ION Decentralised input module IP67 for PNOZmulti 773 600 EC declaration of conformity This product these products meet the requirements of the directive 2006 42 EC for ma chinery of the Euro...

Отзывы: