Pilz 506 255 Скачать руководство пользователя страница 22

 

The Best of 

German 

Engineering

Partner of:

Support

Technical support is available from Pilz round the clock. 

Americas

Brazil

+55 11 97569-2804

Canada

+1 888-315-PILZ (315-7459)

Mexico

+52 55 5572 1300

USA (toll-free)

+1 877-PILZUSA (745-9872)

Asia

China

+86 21 60880878-216 

Japan

+81 45 471-2281

South Korea

+82 31 450 0680

Australia

+61 3 95600621

Europe

Austria

+43 1 7986263-0

Belgium, Luxembourg

+32 9 3217575

France

+33 3 88104000

Germany

+49 711 3409-444

Ireland

+353 21 4804983

Italy, Malta

+39 0362 1826711

Scandinavia

+45 74436332

Spain

+34 938497433

Switzerland

+41 62 88979-30

The Netherlands

+31 347 320477

Turkey

+90 216 5775552

United Kingdom

+44 1536 462203

You can reach our  
international hotline on:  

+49 711 3409-444  
[email protected]

CMSE

®

, Indur

aNET p

®

, P

AS4000

®

, P

AScal

®

, P

ASconfig

®

, P

ilz

®

, PIT

®

, PLID

®

, PMCprimo

®

, PMCpr

ot

ego

®

, PMCt

endo

®

, PMD

®

, PMI

®

, PNO

Z

®

, P

rimo

®

, PSEN

®

, PSS

®

, PVIS

®

, SafetyBUS p

®

,  

SafetyEYE

®

, SafetyNET p

®

, THE SPIRIT OF SAFET

Y

®

 ar

e r

egist

er

ed and pr

ot

ect

ed tr

ademarks of P

ilz GmbH & Co. K

G in some countries. W

e would point out that pr

oduct featur

es may var

 

from the details stat

ed in this document, depending on the status at the time of publication and the scope of the equipment. W

e accept no r

esponsibility for the validity, accur

acy

  

and entir

ety of the t

ext and gr

aphics pr

esent

ed in this information. Please contact our T

echnical Suppor

t if you have any questions.

Pilz develops environmentally-friendly products using  
ecological materials and energy-saving technologies.  
Offices and production facilities are ecologically designed, 
environmentally-aware and energy-saving. So Pilz offers 
sustainability, plus the security of using energy-efficient  
products and environmentally-friendly solutions.

Pilz GmbH & Co. KG 
Felix-Wankel-Straße 2 
73760 Ostfildern, Germany
Tel.: +49 711 3409-0 
Fax: +49 711 3409-133 
[email protected]
www.pilz.com

200XXXX-EN-0X

0-0-2-3-000, 2017-00 P

rint

ed in Germany

© P

ilz GmbH & Co. K

G, 2017

Back cover

22226-EN-03, 2018-12 Printed in Germany

© Pilz GmbH & Co. KG, 2015

Содержание 506 255

Страница 1: ...PSEN ma1 3b 28 VA Operating Manual 22226 EN 03 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...el 6 Warranty and liability 6 Disposal 6 For your safety 7 Unit features 7 Function description 8 Block diagram 8 Operating distances 9 Lateral and vertical offset 9 Wiring 10 Pin assignment 10 Requir...

Страница 4: ...is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preven...

Страница 5: ...5 3 PDDB only in connection with the actuator PSEN ma1 3 08 EX VA the interface PSEN ix1 and the suitable evaluation devices see Requirements and connection to evaluation devices 11 The following is d...

Страница 6: ...ate devices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsi...

Страница 7: ...witch from the supply voltage WARNING Ignition spark from cable separator connector within the potentially explosive area can trigger an explosion When the cable separators connectors are used within...

Страница 8: ...h are closed and the LED will light The safety switch is designed for applications in series connections Operate the PSEN ma1 3b 28 VA in conjunction with the following components Actuator PSEN ma1 3...

Страница 9: ...Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independent values for the switching distances are included in the Technical details 18 Late...

Страница 10: ...ed the overall cable resistance must be checked before commissioning it may also be necessary to check the cross circuit detec tion function Make sure that the safety switch cable extends from the EX...

Страница 11: ...1p PNOZ e6vp PNOZ e6 1p PNOZpower for safety gate monitoring PNOZ p1p PNOZ p1vp PNOZsigma for safety gate monitoring PNOZ s3 PNOZ s4 PNOZ s5 PNOZ X for safety gate monitoring PNOZ X2 PNOZ X2 5P PNOZ X...

Страница 12: ...ma1 3b 28 VA Outputs at the evaluation device must only be switched on again when both reed con tacts at the safety switch have been opened and closed partial operation lock INFORMATION Risk time in...

Страница 13: ...2 41 43 44 42 A1 A2 1 2 3 4 11 12 14 13 1 2 3 4 21 22 24 23 1 2 3 4 31 33 34 32 1 2 3 4 41 43 44 42 24 V I0 0 I0 1 I0 2 I0 3 24 V 0 V PSEN ix1 PLC PSENmag 0 V A2 A1 Evaluation device Input circuit Inp...

Страница 14: ...3 1 2 4 11 12 13 14 3 1 2 4 5 6 Brown White Blue Black PNOZ s3 Non Ex area Ex area S21 S22 S11 S12 PNOZ s3 PSENmag 3 1 2 4 5 6 PSEN ix1 3 1 2 4 11 12 13 14 Brown White Blue Black Auxiliary contact wi...

Страница 15: ...operties The unit s properties may be affected if installed in an environment contain ing electrically or magnetically conductive material Please check the operating distances and the assured release...

Страница 16: ...tor cannot be used as an end stop Circumvention of the safety switch in a reasonably foreseeable manner must be preven ted Please note the installation measures in accordance with EN ISO 14119 for a p...

Страница 17: ...tch and actuator are installed according to the specifications Installation 15 Operating distances may deviate if other arrangements are used Note the maximum permitted lateral and vertical offset see...

Страница 18: ...3 PDDB Electrical data Supply voltage Voltage 24 V Kind DC Voltage tolerance 20 10 Max switching frequency 1 Hz Lowest operating current Im 1 mA Max voltage drop Ud 0 5 V Switching voltage 24 V Intern...

Страница 19: ...e Pollution degree 3 Rated insulation voltage 30 V Rated impulse withstand voltage 0 8 kV Protection type Housing IP67 IP69 Mechanical data Actuator 1 PSEN ma1 3 08 EX VA Typ Hysteresis 3 mm Operating...

Страница 20: ...ata in order to achieve the required safety level for your plant machine Operating mode B10d in accordance with EN ISO 13849 1 2015 and EN 62061 TM year in accordance with EN ISO 13849 1 2015 2 channe...

Страница 21: ...switches PSEN ma 535 120 EC declaration of conformity This product these products meet the requirements of the following directives of the European Parliament and of the Council 2006 42 EC on machines...

Страница 22: ...yNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depe...

Отзывы: