2-22
Other Limitations
2-22-1
All Passenger Seats
For takeoff and landing the seat lap and shoulder belts must be fastened, the lap belt
tightened, and the seat headrest positioned to support the head.
2-22-2
Luggage Limitations
The luggage area maximum load is given in
. The load is dependent on the
aircraft interior configuration and the Part No. of the luggage net installed.
Table 2-22-1: Luggage Limitations
Interior Configuration
Maximum load with luggage net
525.25.12.043 installed
STD-9S
265 lb (120 kg)
EX-6S-STD-2S
265 lb (120 kg)
EX-4S-STD-4S
265 lb (120 kg)
EX-6S-2
400 lb (180 kg)
EX-8S
400 lb (180 kg)
A Luggage Net must be installed at frame 34 when luggage is stowed.
The luggage area maximum load is 500 lb (225 kg) with an extendable luggage net installed.
The extendable luggage net Part No. 525.25.12.026 and/or any luggage may not extend in
front of frame 32. If the extendable luggage net is used, there must be a clear area in front of
the net as follows:
−
At least 280 mm forward of frame 32, when the net floor attachments are placed at frame
32 (the most forward position of the net)
−
At least 340 mm forward of frame 34, when the net floor attachments are placed at frame
34.
2-22-3
Cargo Limitations
Maximum Freight Load 3300 lbs (1500 kg).
Cargo must be arranged to permit free access to the passenger door and the right hand
emergency overwing exit. No cargo must be placed on the seats.
All cargo must be secured by approved cargo restraints as described in Section 6,
. Tie Down Straps with a breaking strength of at least 1800 lb per
strap must be used.
All Cargo/Containers must be located against a retaining bar secured laterally to the seat rails.
Items up to a total weight of 66 lb (30 kg) can be stowed in the cabin area without being
strapped down providing a cargo net is installed in front of the items.
Cargo nets may only be installed on the attachments at Frames 24 and 27.
No passengers must be seated rearward of a cargo net.
If an extendable baggage net is used the tie down fittings and the cargo strap fittings must
have a minimum space of 5 inches between the fittings.