Name
Identifications/References
Qty
Reference
Remark
Stop watch
Part Local supply
AR
Decade resistance box
Part Local supply
2
OAT simulator
Part T30-005
2
Maintenance box
Part T45-005
AR
Jumper wire
Part Local supply
AR
Propeller de-ice test set
Part T30-010
1
Supplies
Table 4 Supplies
Name
Identifications/References
Qty
Reference
Remark
Lockwire
Part P02-007
AR
Spares
Table 5 Spares
Name
Identifications/References
Qty
Reference
Remark
None
Safety Conditions
CAUTION
TURN THE PROPELLER SLOWLY BY HAND DURING THIS TEST. THIS WILL MAKE SURE THAT THE
BRUSH BLOCK DOES NOT BECOME TOO HOT.
CAUTION
DO NOT OPERATE THE PROPELLER DE-ICE SYSTEM ABOVE 38 °C (100 °F) AMBIENT TEMPERATURE
FOR MORE THAN 5 MINUTES. LET THE DE-ICE BOOTS BECOME COOL BEFORE YOU DO THE TEST
AGAIN.
Note
To identify the AGE and tools used in this procedure refer to the List of AGE and Tools, TEM
12-B-00-00-00-00A-
060A-A
.
Note
To identify the consumable items used in this procedure refer to the Consumable Materials List, AMM
12-B-20-31-
00-00A-070A-A
.
Procedure
1
General
This data module gives the test procedures to do an operational test or a functional test of the
propeller de-ice system.
The operational test is necessary:
−
If required for scheduled maintenance
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-30-60-00-00A-903C-A
UNCLASSIFIED
2021-12-04 Page 2