Safety Conditions
Note
To identify the Aerospace Ground Equipment (AGE) and tools used in this procedure, refer to the List of AGE and
Tools, TEM
12-B-00-00-00-00A-060A-A
.
Procedure
1
Obey the safety precautions given in AMM 12-B-24-00-00-00A-901A-A.
2
Open and install a Safety clip - Circuit breaker hold open (Pt.No. T12-030) on these circuit breakers:
−
N ESS (RIGHT HAND POWER JUNCTION BOX)
−
AV 2 (RHPJB)
−
MAIN (RHPJB)
−
U/FLOOR HTR (RHPJB)
−
HYD PWR (RHPJB)
−
GEN 2 (RHPJB)
−
F/WARMER (RHPJB) (if installed)
−
RH W/SHLD (RHPJB)
−
STARTER (ESSENTIAL BUS)
−
IGNITION (ESSENTIAL BUS)
−
FUEL CTL (ESSENTIAL BUS)
−
LH FUEL PUMP (ESSENTIAL BUS)
−
RH FUEL PUMP (ESSENTIAL BUS)
−
FLT CONT CH B (AVIONIC 2 BUS)
−
TAXI LIGHT CTL (GENERATOR 2 BUS)
−
MAINT I/F (NON ESSENTIAL BUS)