XBS-200
User Manual
Version 02

4 Configuration via the USB Console

This description is based on an Ubuntu System with minicom installed.

Ubuntu 16.04.6 LTS
minicom Version 2.7 (kompiliert am Nov 15 2018)

Main features of the console:

File upload

Rename/Move files from r/w to secure partition

Cat files

Show hexdumps of a file

Execute bg96 start scripts

Check sensor values

Activate/deactivate sensors

Dump settings

Configure msi/txt

Delete log files

Show system informations

The command 'help' or '?' prints a short list of all known commands.

4.1.1 Settings of the Serial Connection

Device: 

/dev/ttyACM<x>

Connection: 115200 8N1

Connect with minicom and press enter to see if the console is working properly. It happens sometimes
that the USB-driver could not connect to the XBS. If the dmesg reports an error please reboot the 
Linux system. Then the connection work properly again.

4.1.2 File Upload

Start the minicom in this directory where the file for upload is located.

Enter the command 'write' the filename for xbs and the file size in Bytes. The filename can be 
different from the name on the linux host system.

console> write at.txt 607

1. press <crtg>+<a> then <s>
2. from the upload menu select xmodem
3. select the file from the Linux file system

© 2020 pikkerton GmbH

XBS-200_Manual_v02.odt

Page 12/21

Содержание XBS-200

Страница 1: ...XBS 200 User Manual Version 02 History Version Date Changes Status 01 12 07 2019 Born 02 15 04 2020 Various Adaptions 1st Release Release 2020 pikkerton GmbH XBS 200_Manual_v02 odt Page 1 21...

Страница 2: ...l errors or omissions contained herein Furthermore they shall not be liable for any damages that are directly or indirectly attributable to the furnishing performance or use of this material Changes t...

Страница 3: ...2 File Upload 12 4 1 3 Rename Move Files 13 4 1 4 Cat files 13 4 1 5 Show hexdumps of a file 13 4 1 6 Check sensor values 13 4 1 7 Activate deactivate sensors 14 4 1 8 Dump settings 14 4 1 9 Configur...

Страница 4: ...XBS 200 User Manual Version 02 1 Hardware Device 2020 pikkerton GmbH XBS 200_Manual_v02 odt Page 4 21...

Страница 5: ...r supply is required The connector on the device side is Mini USB B For devices with LTE modem in GSM mode a 2 0 Amp power supply unit is required otherwise a 1 0 Amp model is sufficient For configura...

Страница 6: ...r under the battery holders An incorrect battery configuration can damage the device Possible battery configurations Battery type Qty of cells Used socket 1 5V 2 BATT1 BATT3 1 5V 4 BATT1 BATT2 BATT3 B...

Страница 7: ...ty The polarity is printed on the circuit board under the batteries Reverse polarity can lead to the destruction of the device the batteries and the risk of injury As soon as the batteries are inserte...

Страница 8: ...necessary to activate the USB interface USB is deactivated in battery mode to save power Connect the USB cable to the PC and the XBS 200 and trigger a reset with the button After the reset the XBS 200...

Страница 9: ...em on the XBS which contains two partitions 2 1 Secure Partition This partition is used to store general settings and script files 2 2 R W Partition This partition is used for log files and as file up...

Страница 10: ...lds are violated or not If none of the thresholds are violated the controller will enter deep sleep mode without sending anything The thresholds can be either MIN or MAX values or also DELTA values Th...

Страница 11: ...Lux UV Index 3301 1 5700 xbs 200 Serial UVI Air Pressure 3315 0 5700 xbs 200 Serial PRES Pa CO2 3325 0 5700 xbs 200 Serial CO2 ppm TVOC 3325 1 5700 xbs 200 Serial TVOC mg m 3 ECO2 3325 2 5700 xbs 200...

Страница 12: ...Settings of the Serial Connection Device dev ttyACM x Connection 115200 8N1 Connect with minicom and press enter to see if the console is working properly It happens sometimes that the USB driver coul...

Страница 13: ...sensor data for all existing and activated sensors console sensors BRI Sensor not active UVI Sensor not active PRES 101839 695 Pa TEM 25 528 C HUM 25 993 ECO2 400 000 ppm TVOC 0 000 ppm ACC Sensor NOT...

Страница 14: ...editable values can be displayed using the DUMP command see dump settings 4 1 8 Dump settings All variables can be displayed using the DUMP command Variable names are required for example to activate...

Страница 15: ...uration it may make sense to delete the Log Files in order not to unnecessarily inflate the files with false alarms console rm system log Delete file successful LOG files in the R W partition can be s...

Страница 16: ...ax timeout ms at command cr lf At least a cr or lf must be placed at the end of a line Emplty lines are allowed Max script file size 3000kB NB1 only no M1 300 AT QCFG iotopmode 1 1 use LTE technology...

Страница 17: ...nsole cat atCommand log AT QCFG iotopmode 1 1 OK AT QCFG nwscanmode 0 1 OK AT QCFG nwscanseq 030102 1 OK AT QCFG band 0 0 80 1 OK AT COPS 1 2 26201 9 OK If the script is working properly and should be...

Страница 18: ...0 s max_logfile_size const_int max logfile size Bytes bg96_enable onoff Enables the bg96 module bg96_psm onoff Enables psm of the bg96 module wifi_enable onoff Enables the wifi module ble_enable onoff...

Страница 19: ...t Upper Threshold for BRI bri_delta float Delta Threshold for BRI uv_lt float Lower Threshold for the UV Index 0 0 100 0 uv_ht float Upper Threshold for the UV Index 0 0 100 0 uv_delta float Delta Thr...

Страница 20: ...s the pulse counting pc_value int Last pulse counter value contact_enable onoff Enables the contact monitoring pc_contact_dbt int Debounce time of the pulse counter ms wlan txt ip_ap ip IP Address of...

Страница 21: ...nable on console set bg96_enable off bg96_enable off OK console get bg96_enable bg96_enable off console 6 3 Remarks 6 3 1 lwm2m_server The lwm2m server setting has to follow the format coap IP or URL...

Отзывы: