background image

 

 

Tel: +49(0)3641/66880 • Fax: +49(0)3641/668866 • 

[email protected]

 

• www.piezosystem.de  

22

 

 

5. 

Safety instructions 

 

Do not open the units! There are no user serviceable parts inside. Opening 

or  removing  covers  may  expose  you  to  dangerous  shock  hazards  or  other 
risks. For servicing please refer to qualified service personnel. 

 

Allow  adequate  ventilation  around  the  units  so  that  heat  can  properly 

dissipate.  Do  not  block  ventilated  openings  or  place  the  units  near  a 
radiator, oven or other heat sources. Do not put anything on top of the units 
except accessory designed for that purpose (e.g. actuators). 

 

Do not spill any liquids into the cabinet or use the units near water. 

 

Do  not  insert  objects  of  any  kind  into  the  cabinet  slots,  as  they  may  touch 

dangerous  voltage  points,  which  can  be  harmful  or  fatal  or  may  cause 
electric shock, fire or equipment failure. 

 

Do  not  place  any  heavy  objects  on  any  cables  (e.g.  power  cords,  sensor 

cables, actuator cables, optical cables). Damage may cause malfunction or 
shock or fire! 

 

Do not place the units on a sloping or unstable cart, stand or table as they 

may fall or not work accurately. 

 

Work  with  the  units  only  in  a  clean  and  dry  environment!  Only  specially 

prepared units (e.g. actuators) can work under other conditions! 

 

Please use only original parts from 

piezosystem jena

 

piezosystem  jena

  does  not  give  any  warranty  for  damages  or  malfunction 

caused  by  additional  parts  not  supplied  by 

piezosystem  jena

.  Additional 

cables  or  connectors  will  change  the  calibration  and  other  specified  data. 
This  can  change  the  specified  properties  of  the  units  and  cause  them  to 
malfunction. 

 

Piezoelements  are  sensitive  systems  capable  of  the  highest  positioning 

accuracy.  They  will  demonstrate  their  excellent  properties  only  if  they  are 
handled correctly! Please mount them properly only at the special mounting 
points. 

 

Immediately  unplug  your  unit  from  the  wall  outlet  and  refer  servicing  to 

qualified service personnel under the following conditions: 

o

 when the power supply cord or plug is damaged 

o

 if liquid has been spilled or objects have fallen into the unit 

o

 if the unit has been exposed to rain or water 

o

 if the unit has been dropped or the housing is damaged 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 12V40 Series

Страница 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...

Страница 2: ...41 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 17 Instruction Manual Voltage Amplifier 12V40 Series Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...nstructions for checking the function of the system quick start 23 7 How to operate the 12V40 24 7 1 Technical data 24 7 2 Initialization 25 7 3 Service 25 7 4 SMB modulation input MOD 26 7 5 SMB monitor output socket MON 26 7 6 Actuator socket OUT 26 7 7 Switch closed loop 12V40SG 12V40CLE 26 7 8 Wiring of the rear panel connector 27 7 9 Possibilities of the error correction 29 8 Your notes 30 Ar...

Страница 4: ...ries contains following amplifiers 12V40 12V40SG 12V40CLE 24V40 24V40SG 24V40CLE 12V40C und 12V40CSG This manual also offers you additional information about piezoelectric products 2 Certification of piezosystem jena The company piezosystem jena GmbH has been certified by DIN EN ISO 9001 2000 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 5: ...Tel 49 0 3641 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 20 3 Declaration of conformity Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 6: ...plication can cause damage to the actuator Heating of the ceramic material will occur during dynamic operation and is caused by structure conditional loss processes This may cause failure if the temperature exceeds specified values cited below With increasing temperature up to the Curie temperature usual values approx 140 C 250 C the piezoelectric effect disappears Piezoelectric actuators such as ...

Страница 7: ...or unstable cart stand or table as they may fall or not work accurately Work with the units only in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please use only original parts from piezosystem jena piezosystem jena does not give any warranty for damages or malfunction caused by additional parts not supplied by piezosystem jena Additional c...

Страница 8: ...hipment The secondary voltage DC matches with the amplifier Connect the power cable Connect the piezo element by using the LEMO connector Turn off closed loop 12V40SG 12V40CLE Switch on the power supply The red LED indicates the amplifier is working By turning the potentiometer to its maximum position the actuator will reach its maximum movement Offset is accomplished by the offset potentiometer o...

Страница 9: ...0 5A 24V DC dimensions BxHxT mm 173mm x 130mm 105mm x 45mm mass g 800 channels 1 output power W 6 output current mA 40 output voltage OUT 10 150 V output connector OUT LEMO 0S 302 modulation input MOD 0 10V SMB inner resistance 10kΩ monitor voltage MON 1 15V SMB 0 10V on SG CLE 0 10V rear panel Inner resistance 100kΩ SMB 10kΩ rear panel output noise 0 3 mVRMS 500Hz bandwidth Hz 400 polarity positi...

Страница 10: ... the ceramics and increase the MTBF In addition the OVL LED lights up in the case of a limit error No automatic disconnection of the overvoltage occurs in that case To guarantee stable temperature circumstances we recommend to switch on the amplifier approx 2 hours before the measurement in the sub µm range takes place A constant temperature environment is necessary for precise positioning tasks P...

Страница 11: ...nt devices 100kΩ should be used The output is short protected please avoid injected voltages 12V40SG 12V40CLE The measuring voltage 0 10V is available at this socket and can be monitored by using an analogue oscilloscope This is especially recommended for dynamical operation Pay attention to the inner resistance of the monitor output only high ohmic measurement 100kΩ devices should be used The out...

Страница 12: ... control by HIGH or LOW TTL level HIGH Pin 7 is active OFFSET potentiometer and MOD modulation input at the front panel are switched off LOW Pin 7 is not active motion of the actuator will be controlled by the OFFSET potentiometer and the MOD modulation input at the front panel 12 OUT output voltage Uout 10 150V option 15 GND ground operating voltage 16 PWR operating voltage table 2 pin wiring of ...

Страница 13: ...rol by HIGH or LOW TTL level HIGH Pin 7 is active OFFSET potentiometer and MOD modulation input at the front panel are switched off LOW Pin 7 is not active motion of the actuator will be controlled by the OFFSET potentiometer and the MOD modulation input at the front panel 24 OUT output voltage Uout 10 150V option 30 GND ground operating voltage 32 PWR operating voltage table 3 pin wiring of the r...

Страница 14: ...ease check the modulation input and offset table 4 possibilities of the error correction The equipment concept makes adaptations to customer preferences concerning the technical threshold values such as the main voltage or the output voltage possible Please contact our technical service department in order to discover the possibilities for your specific problem Any adjustments necessary are to be ...

Страница 15: ...Tel 49 0 3641 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 30 8 Your notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 16: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: