background image

RSE  

 

Smart GAS meter  

RSE/2001 LA 

 RSE/2,4 

 

Use and Maintenance Manual 

Point-Multipoint Version (PM)

 

Rev.

 

8

 

Date

 

20/07/2015

 

 

 

 

 

Содержание RSE/2,4

Страница 1: ...RSE Smart GAS meter RSE 2001 LA RSE 2 4 Use and Maintenance Manual Point Multipoint Version PM Rev 8 Date 20 07 2015 ...

Страница 2: ...ral description 8 4 Main functions 10 4 1 On off valve 10 4 1 1 Procedure for opening the valve through the user interface 10 4 2 Digital outputs 10 4 3 Data recording 10 4 4 Acquisition 11 4 5 Events and diagnostics 11 4 6 Activation 11 4 7 Communication 11 4 8 User interface 12 5 Installation 12 5 1 Mechanics installation 12 5 2 Connection to the system 13 5 2 1 Using the ZVEI probe 13 5 3 Power...

Страница 3: ...ference conditions in the previous billing period 20 7 1 7 Totalizer of volumes subject to alarm in the previous billing period 20 7 1 8 Totalizer of volumes for price range 1 in the previous billing period 21 7 1 9 Totalizer of volumes for price range 2 in the previous billing period 21 7 1 10 Totalizer of volumes for price range 3 in the previous billing period 21 7 1 11 Invoice date 21 7 1 12 D...

Страница 4: ...nce Manual PM Version ENGLISH ISV065UTE Rev 8 Date of issue 04 06 2014 Revision 8 Revision date 20 07 2015 Page 4 of 32 10 Technical characteristics 31 10 1 General features 31 10 2 Communication ports 32 10 3 Feeding devices 32 ...

Страница 5: ...h application starting from the firmware release LR 1 09 NLR 2 22 RSE 2001 LA and RSE 2 4 are available in different models with the following main common features IP 55 protection Integrated temperature sensor Local optical communication port complying with CEI EN 62056 21 ZVEI LCD display 3 front keys user interface The various models differ in the following features Type of modem o Wireless M B...

Страница 6: ...r operation seat already electrically connected RSE 2001 LA G4 WM169 pmax 0 5 bar Classe 1 5 tm 25 C 55 C tb 15 C tsp 15 C V 1 2 dm Qmin 0 04 m h Qt 0 6 m h Qmax 6 m h T H3 OIML R137 1 2 2012 EN 1359 1998 A1 2006 SMGR0340YYXXXXXX M15 0122 T10683 Vernate Milano II 3G Exic IIB T3 Gc CEC 14 ATEX 011 25 C Tamb 55 C IP55 M2 E2 2015 RSE 2 4 G6 WM169 Pmax 0 5 bar Classe 1 5 Tm 25 C 55 C Tb 15 C Tsp 15 C ...

Страница 7: ...twear and of a damp cloth 65 is recommended during the installation maintenance Further information can be found in CEI 50404 Pietro Fiorentini SpA denies all liabilities resulting from the risks and consequences caused by the non compliance with these provisions 2 2 Connecting to other devices There is no RSE connection with external devices RSE can connect using the ZVEI optical port to devices ...

Страница 8: ...nt temperature WARNING Install in a compartment that meets the provisions in force on safety away from any possible damage of mechanical origin away from sources of heat or open flames in a dry place and protected from external agents Install with the indicator device in a horizontal position not in contact with the wall and raised with respect to the floor During installation avoid mechanical str...

Страница 9: ... 1 5 or 1 upon request as defined in Directive 2004 22 EC MID RSE is able to count the amount of gas that has passed through the meter in different consumption ranges in relation to the time in which it was measured in compliance with the provisions of the resolution 631 2013 R GAS issued by AEEGSI on 27 12 2013 Metal enclosure Plastic enclosure Radio transmission battery not replaceable Metrologi...

Страница 10: ...lly by activating the keyboard according to a special procedure see chapter 4 1 1 The opening of the previously closed valve must be authorized in advance by the SAC Control Center It is possible to display the status of the valve in the related SV menu see chapter 6 and chapter 7 1 18 To reactivate a previously closed valve RSE must have first of all received the authorization for opening from th...

Страница 11: ... sensors The piloting of the sensors is carried out in a controlled manner which is such as to assure proper operation during the whole RSE life cycle The measurement of the temperature required for the calculation of the volumes on the reference thermodynamic conditions is carried out using a temperature sensor with a resolution of 10 bits which provides a measurement in Kelvin degrees with a res...

Страница 12: ...r use in Zone 2 atmospheres therefore it is safe in case of operation without interferences IIB It establishes the maximum ignition energy that shall not be exceeded and therefore with what types of gas the product can be used in a safe manner e g ethylene T3 It defines the maximum allowable surface temperature equal to 200 C Caution Before beginning with the installation read and verify the safet...

Страница 13: ... on the customer side are closed Slowly load the RSE meter with pressure If on the meter a piping for pressure measurement has been subsequently installed check the tightness of the related connection After leak testing slowly remove pressure to the RSE meter Once the tightness has been checked the meter is ready for use The meters of the company SAMGAS require no maintenance WARNING When the mete...

Страница 14: ... test 1 cycle per month Ambient temperature profile 5 of the time at 25 C 20 of the time at 10 C 50 of the time at 22 C 20 of the time at 55 C 5 of the time at 70 C RSE implements and manages service quality logs available only through the communication channels not on the display able to verify the deviation of the actual operating conditions from the reference ones 5 3 1 Connecting the batteries...

Страница 15: ...l seal and without permanently damaging the metrological cover Access to the replaceable communication battery is not possible without leaving a record of the event in the Metrological Log of the meter Using interface equipment usually available to the user it is only possible to read the data and it is not possible to perform any configuration The configurations that can be performed through the ...

Страница 16: ...uirements of MID and EN12405 1 The construction technology of the LCD element display is such as to assure a lifetime of over 15 years under operating conditions which include also prolonged exposure to sunlight The meaning of the graphical elements is outlined in the following table Menu field Each menu can be identified by a letter or a combination of letters and numbers Units of measurement fie...

Страница 17: ...rence conditions for range 2 Totalizer of volumes under reference conditions for range 3 Added to T TA T1 T2 or T3 When the count refers to previous billing periods Invoice date Diagnostics Message to the user ID of the re delivery point Status of the valve Status of the device Maximum conventional flow rate Date Hour Current price range 6 2 3 Units of measurement field Icon Meaning Notes When a t...

Страница 18: ...munication active General warning Active alarm Alarm not active but previously recorded and not yet displayed Low battery Low battery to be replaced residual charge 10 Temperature alarm Active alarm Alarm not active but previously recorded and not yet displayed Authentication required Authentication required to access the submenu functions Authentication performed Authentication occurred It is pos...

Страница 19: ...le to move to next page Some menus consist of various submenus in this case the letter E Enter is displayed on the lower right corner of the display By pressing the green Enter button the submenu appears By pressing the up and down buttons it is possible to navigate inside the submenus 7 1 Chapters The various menus are identified by the letters shown on the display under menu field Here below the...

Страница 20: ...tion T2 Format 5 integers and 3 decimals Unit m Pressing enter Legal relevance YES 7 1 5 Totalizer of volumes for price range 3 in the current billing period Abbreviation T3 Format 5 integers and 3 decimals Unit m Pressing enter Legal relevance YES 7 1 6 Totalizer of volumes under reference conditions in the previous billing period Abbreviation T PRE Format 5 integers and 3 decimals Unit m Pressin...

Страница 21: ...1 9 Totalizer of volumes for price range 2 in the previous billing period Abbreviation T2 PRE Format 5 integers and 3 decimals Unit m Pressing enter Legal relevance YES 7 1 10 Totalizer of volumes for price range 3 in the previous billing period Abbreviation T3 PRE Format 5 integers and 3 decimals Unit m Pressing enter Legal relevance YES 7 1 11 Invoice date Abbreviation DF Format dd mm yy Unit Pr...

Страница 22: ...igured or under maintenance 0 device configured 6 1 Memory error 5 1 Flow rate error 4 1 Device generic error 3 1 Measurement algorithm error 2 1 Metrological Event Log 90 1 1 Metrological Event Log complete 0 1 Clock synchronization failed The 16 bits mentioned above are represented using a hexadecimal encoding 0 F by sets of 4 as shown below BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 DIGIT 4 3 2 ...

Страница 23: ...alve Abbreviation SV Pressing Enter Press the central button to access the valve menu The menu structure is shown below To enter the password using the up and down buttons to select the numbers then press the enter button to confirm To perform the leak testing press the Enter button Here below there are all the submenus menu id Operation Description VAL 00 A 00 C 00 r Open valve Closed valve Valve...

Страница 24: ...2 00 01 02 Setting of the counting resolution 00 operation not yet preformed 01 operation performed successfully 02 operation failed 02 03 00 01 02 Setting of the normal resolution 00 operation not yet preformed 01 operation performed successfully 02 operation failed 03 Display of the read temperature 04 00 07 Setting of the display contrast Press enter and then the up down keys to select the desi...

Страница 25: ...isabling of the ZVEI port 1 From the main SD menu press the central button to access the submenu ZVEI port status Disabled 2 Press the lower button once Submenu to enable the ZVEI port 3 Press the central button The operation was completed successfully 4 Press the upper button once ZVEI port status Enabled 5 Press the lower button twice Submenu to disable the ZVEI port ...

Страница 26: ...VEI port status disabled 7 1 16 2 Enabling and disabling of the counting for the test phase 1 From the main SD menu press the central button to access the submenu 2 Press the lower button three times The meter is counting with normal resolution 3 Press the lower button Menu to set the counting in high resolution 4 Press the central button The operation was completed successfully 5 Press the upper ...

Страница 27: ...ress the lower button twice Menu to set the counting in low resolution 7 Press the central button The operation was completed successfully 8 Press the upper button twice The meter is counting with normal resolution 7 1 17 Maximum conventional flow rate Abbreviation Qconv_max Format 2 integers and 3 decimals Unit m h Pressing Enter Legal relevance YES ...

Страница 28: ...elease Release date Release time CRC16 Boot module CRC16 Header module CRC16 Loader module CRC16 Hal module CRC16 Kernel module CRC16 Stm32lib module CRC16 KSystem module CRC16 Security module CRC16 Display module CRC16 Metric module CRC16 Plugin header CRC16 Plugin module System global uptime days including low power and running mode System global uptime h m s including low power and running mode...

Страница 29: ...g of the last 32 firmware updates For each firmware updates a block of three submenus is added CRC16 LR of the firmware Updating date Updating time The firmware loaded at the factory is the oldest entry date and time set to 00 00 00 If the download fails four dashes are displayed instead of CRC 16 LR Legal relevance YES 7 1 20 Current rate Abbreviation Fn Format 1 digit Possible values 1 Range 1 2...

Страница 30: ...refore it is not necessary to replace it The 169 MHz transmission battery is sized to assure an autonomy of more than 15 years under normal environmental and operating conditions see paragraph 10 3 and therefore it is necessary to replace it 9 1 2 Firmware update In case of release of a new firmware version the notes that describe the changes made since the previous version are distributed The fir...

Страница 31: ...ith segments Resistance to high temperatures T Resistance to high temperatures EN 1359 1998 A1 2006 paragraph 6 5 5 Keyboard 3 front operator keys Operating storage temperature 25 C to 55 C 25 C to 60 C Certifications Atex Ex ic 3G IIB T3 Gc MID Metrological battery Type Format Autonomy 3 6 V lithium battery Size C 15 years Transmission battery Type Format Autonomy 3 6 V lithium battery Size C 15 ...

Страница 32: ...d circuit board The cell is fastened inside the meter it cannot be replaced and it is protected by metrological seals 169 MHz radio battery The radio version has an additional non replaceable battery placed in the metrological area and therefore not accessible by the operator A single non rechargeable cell with Lithium Thionyl chloride technology Li SOCl2 is used The main features are Size C with ...

Отзывы: