MAINTENANCE
4-12
/ Husky 12 Foam System
© 2017 Pierce Manufacturing Inc. All Rights Reserved.
4-6.5
Set Concentrate Default Percentages
MODE SELECT
→
SETUP SELECTION
→
SETUP
→
PERCENT DEFAULTS
NOTE:
•
The default percentage is set at the factory to automatically run at 0.5% for Class A foam and
3.0% for Class B foam. Use this function to adjust the default foam percentages for Class A
and/or Class B.
•
Temporary changes to the foam percentage may be made while running the system by using
the ARROW UP or ARROW DOWN buttons. The department may find it beneficial to change
the defaults for their particular operating requirements or different types or brands of foam.
Figure
4-17:
Setup
Screen
Activation
1557E, 1568A, 1569C
1.
From the normal operation screen (Foam Pump Not Running), navigate to the SETUP screen. Refer to
2.
Use the UP/DOWN buttons to highlight Percent Defaults and press ENTER to bring up the PERCENT
DEFAULTS screen.
Figure
4-18:
Percent Defaults Screen
1582
3.
Use the UP/DOWN arrows to select the desired choice (Class A or Class B).
4.
Press ENTER to activate the line.
5.
Use the UP/DOWN arrows to make the desired adjustments.
6.
When the adjustment is complete, press ENTER to save the setting.
7.
Repeat steps 3 through 6 to make additional adjustments, or press PAGE to go back.
8.
Cycle batteries to confirm changes.
HOLD ENTER AND
PRESS ARROWS
PRESS
PAGE
HOLD 5
SECONDS
SCROLL TO
SETUP
SCROLL TO
SETUP