4.8
SWITCHING SEARCH
SEND
If necessary, you can release the SEARCH-LOCK, by pressing the MARK button (1A) for 3 seconds and placing the
MICRO in the carrying system or covering the sensor.
The MICRO emits an acoustic and tactile (Vibra) warning for 4 seconds that the unit will switch over from Search
to send mode. A tactile send confirmation is performed after the switchover (see also chapter Error! Reference
source not found.).
4.8.1
Secondary avalanche | Auto-Revert Search-to-Send (AR)
The MICRO has the Auto-Revert Search-to-Send (AR) function by default. The unit switches over from Search to
send mode automatically if the unit has not been in motion for 1 minute (buried). You can change the timeout for
the switchover in the PIEPS APP (see also chapter 5).
The AR function has the following features:
Motion-controlled initialization
Short switching time
Long warning phase with signal tone and countdown before switching over
Permanent warning tone, also after switching over
Avalanche
beacon mode
SEARCH
MODE
WARNING PHASE
SEND MODE
Display
indicator
Search
display
Tone output
Search tone
Manual abort
Shake unit or press MARK button
START WARNING
Setting 1 (60 s) 0:30 min
Setting 2 (90 s) 1:00 min
Setting 3 (120 s) 1:30 min
SWITCH TO SEND
1:00 min
1:30 min
2:00 min
During the warning phase, the AR initialization can be interrupted as follows:
By briefly shaking the unit or
By pressing the MARK button
After the switchover, your MICRO sends permanently, including a warning tone, until it is switched off.