18
To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright
in its normal operating position, with the engine switch in position
“
OFF
”.
When transporting the generator:
•
Close the fuel cock
•
Do not overfill the tank (there may not be any fuel in the filler neck).
•
Do not use the generator while it is placed in a vehicle.
•
Take the generator off the vehicle and use it in a well
-
ventilated place.
Before storing the unit for an extended period ( > 2 months):
•
Make sure the storage area is free of excessive humidity and dust.
•
For diesel generating sets it is better to fill the tank completely before storing the generating set for a long time.
In this way you can avoid condensation and corrosion in the diesel tank.
•
Refresh the engine oil.
•
Remove the battery and connect it to a battery charger. This way you will increase the life span of the battery.
MAINTENANCE CONT.
In case there is problem that you cannot solve using this manual, please consult your reseller or the manufacturer!
TRANSPORT & STORAGE
Engine:
See engine manual for maintenance intervals.
-
In the factory, the engine has been filled with coolant for usage down to
-
30°C (
-
22 F).
The specification of this coolant is BS6580/92 –
SAE J1034.
Only use coolant with this specification!
-
In the factory, the engine has been filled with
15W40 oil
(for temperatures down to
-
10°C (14 F)).
The minimum
specification of this oil has to be API SJ/CF
-
4.
-
If the ambient temperature is lower, 10W40 oil
(up to
-
20°C) or
5W40 oil
(down to
-
30°C (
-
22 F)) should be
used. Here the
minimum specification also has to be API SJ/CF
-
4.